Back to Search Start Over

Vascular effects of sirolimus-eluting versus bare-metal stents in diabetic patients: three-dimensional ultrasound results of the Diabetes and Sirolimus-Eluting Stent (DIABETES) Trial

Authors :
Pilar, Jiménez-Quevedo
Manel, Sabaté
Dominick J, Angiolillo
Marco A, Costa
Fernando, Alfonso
Joan Antoni, Gómez-Hospital
Rosana, Hernández-Antolín
Camino, Bañuelos
Javier, Goicolea
Francisco, Fernández-Avilés
Theodore, Bass
Javier, Escaned
Raul, Moreno
Cristina, Fernández
Carlos, Macaya
Source :
Journal of the American College of Cardiology. 47(11)
Publication Year :
2005

Abstract

A predefined intravascular ultrasound (IVUS) substudy was performed to evaluate the vascular effects of sirolimus-eluting stent (SES) versus bare-metal stent (BMS).The Diabetes and Sirolimus-Eluting Stent (DIABETES) trial is a prospective, multicenter, randomized, controlled trial aimed at demonstrating the efficacy of the SES compared with BMS in diabetic patients.Serial intravascular ultrasound analyses were performed in 140 lesions (SES = 75; BMS = 65) immediately after stent implantation and at nine-month follow-up. Vessel, luminal, and stent mean areas and volumes were evaluated at both edges and within the stented segment. Qualitative assessment of residual dissections and stent apposition were also performed.Baseline clinical and angiographic characteristics were similar between groups. At 9 months, in-stent neointimal hyperplasia (NIH) mean area and volume were significantly reduced in the SES group (median NIH area 0.01 mm2 [0.0 to 0.1] vs. 2.0 mm2 [1.0 to 2.9] and median NIH volume 0.11 mm3 [0 to 2.1] vs. 35.3 mm3 [16.6 to 62.6]; both p0.0001). In the SES group, stent edges evidenced significant increase in lumen dimensions mainly due to significant increase in vessel volume, whereas those of the BMS group presented vessel shrinkage leading to significant lumen reduction. Late acquired incomplete stent apposition was observed in 11 lesions (14.7%) in the SES group and 0 in the BMS group (p = 0.001). At one year, no stent thromboses occurred in malapposed stents.The SES implantation effectively inhibits NIH in diabetic patients. The antirestenotic effect of SES is also appreciated at the stent edges. Late acquired stent malapposition is a frequent phenomenon in diabetic patients treated with SES.

Details

ISSN :
15583597
Volume :
47
Issue :
11
Database :
OpenAIRE
Journal :
Journal of the American College of Cardiology
Accession number :
edsair.pmid..........8e42c5f25e279fc0ca1f05091f8d0178