Back to Search
Start Over
Effect of the Pulsatile Extracorporeal Membrane Oxygenation on Hemodynamic Energy and Systemic Microcirculation in a Piglet Model of Acute Cardiac Failure
- Source :
- Artificial organs. 40(1)
- Publication Year :
- 2015
-
Abstract
- The objective of this study was to compare the effects of pulsatile and nonpulsatile extracorporeal membrane oxygenation (ECMO) on hemodynamic energy and systemic microcirculation in an acute cardiac failure model in piglets. Fourteen piglets with a mean body weight of 6.08 ± 0.86 kg were divided into pulsatile (N = 7) and nonpulsatile (N = 7) ECMO groups. The experimental ECMO circuit consisted of a centrifugal pump, a membrane oxygenator, and a pneumatic pulsatile flow generator system developed in-house. Nonpulsatile ECMO was initiated at a flow rate of 140 mL/kg/min for the first 30 min with normal heart beating, with rectal temperature maintained at 36°C. Ventricular fibrillation was then induced with a 3.5-V alternating current to generate a cardiac dysfunction model. Using this model, we collected the data on pulsatile and nonpulsatile groups. The piglets were weaned off ECMO at the end of the experiment (180 min after ECMO was initiated). The animals did not receive blood transfusions, inotropic drugs, or vasoactive drugs. Blood samples were collected to measure hemoglobin, methemoglobin, blood gases, electrolytes, and lactic acid levels. Hemodynamic energy was calculated using the Shepard's energy equivalent pressure. Near-infrared spectroscopy was used to monitor brain and kidney perfusion. The pulsatile ECMO group had a higher atrial pressure (systolic and mean), and significantly higher regional saturation at the brain level, than the nonpulsatile group (for both, P 0.05). Additionally, the pulsatile ECMO group had higher methemoglobin levels within the normal range than the nonpulsatile group. Our study demonstrated that pulsatile ECMO produces significantly higher hemodynamic energy and improves systemic microcirculation, compared with nonpulsatile ECMO in acute cardiac failure.
- Subjects :
- Heart Failure
Spectroscopy, Near-Infrared
Time Factors
Swine
Microcirculation
Renal Circulation
Perfusion
Disease Models, Animal
Extracorporeal Membrane Oxygenation
Animals, Newborn
Regional Blood Flow
Cerebrovascular Circulation
Pulsatile Flow
Acute Disease
Animals
Heart-Assist Devices
Blood Flow Velocity
Oxygenators, Membrane
Subjects
Details
- ISSN :
- 15251594
- Volume :
- 40
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- Artificial organs
- Accession number :
- edsair.pmid..........6f618d3ac41e44146cb346dea5206883