Back to Search Start Over

[Value of dual-energy computed tomography for detection of left atrial appendage thrombus]

Authors :
C L, Schlett
M C, Heidt
A, Jörg
M, Soschynski
S J, Buss
G, Korosoglou
F, Bamberg
H-U, Kauczor
O K, Mohrs
Source :
Der Radiologe. 60(12)
Publication Year :
2020

Abstract

Contrast-enhanced computed tomography (CT) is a convenient method to visualize left atrial appendage (LAA) thrombi. We determined whether diagnostic accuracy improves by including dual-energy as compared to transesophageal echocardiography (TEE). Furthermore, the influence of protocol parameters on radiation dose were quantified.Patients were assigned to the different CT protocols. All CTs were assessed qualitatively for presence of LAA thrombi and dual-energy CT scans quantitatively for iodine concentration. TEE was assessed qualitatively for the presence of thrombi.Of 32 enrolled patients, 6 had a thrombus in TEE. Qualitative CT assessment yielded 83% sensitivity and 88% specificity. In the 26 patients who underwent dual-energy CT, median iodine concentration was 8.6 mg/cmCT provides good diagnostic accuracy for detecting LAA thrombi, which can further be improved if iodine density measurements by dual-energy are incorporated. With an optimized protocol, reasonably low radiation dose can be achieved.

Details

Language :
German
ISSN :
14322102
Volume :
60
Issue :
12
Database :
OpenAIRE
Journal :
Der Radiologe
Accession number :
edsair.pmid..........654dbd606108c4a9916ad514f7b53f5d