Back to Search Start Over

Comparison of PCR Methods for

Authors :
Jessica L, Prince-Guerra
Vitaliano A, Cama
Nana, Wilson
Elizabeth A, Thiele
Josias, Likwela
Nestor, Ndakala
Jacques, Muzinga Wa Muzinga
Nicholas, Ayebazibwe
Yassa D, Ndjakani
Naomi A, Pitchouna
Dieudonne, Mumba
Antoinette K, Tshefu
Guilherme, Ogawa
Paul T, Cantey
Source :
The American journal of tropical medicine and hygiene. 98(5)
Publication Year :
2018

Abstract

Defining the optimal diagnostic tools for evaluating onchocerciasis elimination efforts in areas co-endemic for other filarial nematodes is imperative. This study compared three published polymerase chain reaction (PCR) methods: the Onchocerca volvulus–specific qPCR-O150, the pan-filarial qPCR melt curve analysis (MCA), and the O150-PCR enzyme-linked immunosorbent assay (ELISA) currently used for vector surveillance in skin snip biopsies (skin snips) collected from the Democratic Republic of the Congo. The pan-filarial qPCR-MCA was compared with species-specific qPCRs for Loa loa and Mansonella perstans. Among the 471 skin snips, 47.5%, 43.5%, and 27.0% were O. volvulus positive by qPCR-O150, qPCR-MCA, and O150-PCR ELISA, respectively. Using qPCR-O150 as the comparator, the sensitivity and specificity of qPCR-MCA were 89.3% and 98.0%, respectively, whereas for O150-PCR ELISA, they were 56.7% and 100%, respectively. Although qPCR-MCA identified the presence of L. loa and Mansonella spp. in skin snips, species-specific qPCRs had greater sensitivity and were needed to identify M. perstans. Most of the qPCR-MCA misclassifications occurred in mixed infections. The reduced sensitivity of O150-PCR ELISA was associated with lower microfilaria burden and with lower amounts of O. volvulus DNA. Although qPCR-MCA identified most of the O. volvulus–positive skin snips, it is not sufficiently robust to be used for stop-mass drug administration (MDA) evaluations in areas co-endemic for other filariae. Because O150-PCR ELISA missed 43.3% of qPCR-O150–positive skin snips, the qPCR-O150 assay is more appropriate for evaluating skin snips of OV-16 + children in stop-MDA assessments. Although improving the sensitivity of the O150-PCR ELISA as an alternative to qPCR might be possible, qPCR-O150 offers distinct advantages aside from increased sensitivity.

Details

ISSN :
14761645
Volume :
98
Issue :
5
Database :
OpenAIRE
Journal :
The American journal of tropical medicine and hygiene
Accession number :
edsair.pmid..........4a21df0589267acfe715ce543bc64ed4