Coronary artery compression during intention to treat right ventricle outflow with percutaneous pulmonary valve implantation: incidence, diagnosis, and outcome
- Source :
- Catheterization and cardiovascular interventions : official journal of the Society for Cardiac AngiographyInterventions. 83(7)
- Publication Year :
- 2013
-
Abstract
- Evaluate the incidence, diagnosis, and outcome of coronary compression (CC) during right-ventricular outflow tract interventions.The incidence, risk factors, diagnosis, and outcomes of CC during percutaneous pulmonary valve implantation are poorly defined.One-hundred consecutive patients (May 2008 to January 2012) undergoing transcatheter right-ventricular outflow tract treatment in two institutions were studied.CC occurred in six patients (6%) with a right ventricular outflow conduit stenosis, at a median age of 24.5 (13-49) years. It involved the left main coronary artery in four and the right coronary artery originating from the left anterior descending coronary artery in two patients. Conduit types were homograft (n = 3), bioprosthesis (n = 2), and a pericardial patch (n = 1). Median diameter was 23 (17-24) mm at surgical implantation. CC was diagnosed through a selective coronary angiogram during balloon dilation of the conduit in the first three patients and through an aortic root angiogram for the three next cases because we recognized that proximal compression could be masked during coronary artery cannulation. It was suspected on pre-procedure imaging (magnetic resonance imaging and/or computed tomography) in three cases. Patients with abnormal coronary anatomy tend to be at increased risk of CC (P = 0.0504). One institution had a higher incidence of CC (P = 0.04). CC resolved after balloon deflation. No patient underwent conduit stenting. Four patients underwent surgical reconstruction of right ventricular outflow tract.CC is accurately diagnosed during right-ventricular outflow tract interventions. We recommend an aortic root angiogram during dilation with a non-compliant balloon matching the diameter and length of the intended conduit implant.
- Subjects :
- Adult
Heart Valve Prosthesis Implantation
Male
Cardiac Catheterization
Pulmonary Valve
Adolescent
Incidence
Middle Aged
Coronary Angiography
Pulmonary Valve Insufficiency
Intention to Treat Analysis
Ventricular Outflow Obstruction
Young Adult
Treatment Outcome
Coronary Occlusion
Humans
Female
France
Follow-Up Studies
Retrospective Studies
Subjects
Details
- ISSN :
- 1522726X
- Volume :
- 83
- Issue :
- 7
- Database :
- OpenAIRE
- Journal :
- Catheterization and cardiovascular interventions : official journal of the Society for Cardiac AngiographyInterventions
- Accession number :
- edsair.pmid..........1a58d048cc8d75d2c5a604b3dc505388