COMPARISON QUALITY OF CHEST X RAY OF A NEONATES WITHIN AN INCUBATOR IN RELATION TO THE WITHOUT AN INCUBATOR
- Publication Year :
- 2019
- Publisher :
- Sveučilište u Splitu. Sveučilišni odjel zdravstvenih studija., 2019.
-
Abstract
- Cilj. Cilj istraživanja je dokazati da je tehnička kvaliteta slike lošije tehničke kvalitete kada kazetu za snimanje postavimo ispod nedonoščeta koje ostane u inkubatoru s zatvorenim poklopcem za vrijeme eksponiranja, od one kada kazetu za snimanje postavimo ispod nedonoščeta koje je izvan inkubatora u podlošku za snimanje uz pretpostavku da ekspozicijske parametre ne mijenjamo. Metode. Istraživanje je ustrojeno kao presječno istraživanje na arhivskim podatcima iz arhiva slika EXA PACS sustava pohrane slika Zavoda za Radiologiju Kliničke bolnice Sveti duh, Zagreb. Podaci su prikupljani iz povijesti bolesti, izravnim ocjenom tehničke kvalitete RTG slika srca i pluća nedonoščadi korištenjem Likert-ove ljestvice zadovoljstva tri specijalista radiologije. Uspoređivali smo RTG slike srca i pluća nedonoščadi tako da smo iz arhive slika EXA PACS sustava pohrane slika Zavoda za Radiologiju Kliničke bolnice Sveti duh, Zagreb, koristili samo RTG slike srca i pluća pacijenata koje su nam po načinu izvođenja snimanja za ovo istraživanje odgovarale. Rezultat. Nema značajne povezanosti između ekspozicijskih parametara snimanja u odnosu na tjelesnu masu nedonoščeta i prosječne ocjene tehničke kvalitete RTG snimke srca i pluća nedonoščadi i to bez obzira na način snimanja (s poklopcem inkubatora unutar inkubatora i bez poklopca inkubatora u podlošku za snimanje). Stoga nije moguće odrediti idealne ekspozicijske parametre za idealnu tehničku kvalitetu RTG snimke srca i pluća nedonoščadi. Što se tiče atenuacije zračenja poklopca inkubatora dobili smo rezultat kako poklopac inkubatora atenuira prosječno 24.19 (±0.28) %. Zaključak. Ovim istraživačkim radom utvrdili smo da ne postoji značajna povezanost između ocjene tehničke kvalitete RTG slike srca i pluća nedonoščadi i ekspozicijskih parametara pri snimanju RTG snimke srca i pluća među dvije skupine ispitanika (snimanih u inkubatoru s poklopcem inkubatora te snimanih van inkubatora u podlošku za snimanje). Također, ne postoji značajnija razlika ekspozicijskih parametara u odnosu na tjelesnu masu nedonoščeta niti razlika u ocjeni tehničke kvalitete RTG snimaka srca i pluća nedonoščeta među skupinama (snimani s poklopcem i bez poklopca inkubatora). Međutim, ovim radom smo dobili i zaključak kako poklopac inkubatora atenuira prosječno 24.19 (±0.28) % odnosno kako je apsorbirana doza 24.19 % manja ukoliko je RTG snimanje srca i pluća nedonoščeta izvršeno kroz poklopac inkubatora u odnosnu na snimku van inkubatora u podlošku za snimanje. Aims. The aim of the study is to prove that the technical quality of the image is of inferior technical quality when placed under neonates in the incubator with the lid closed during exposure, than when placed under neonates outside the incubator in the neonates cushion assuming that we do not change the technical parameters. Methods. The research was organized as a cross-sectional study on archival data from the EXA PACS image archives of the image storage system of the Radiology Department of the Clinical Hospital Holy Spirit, Zagreb. Data were collected from the medical history by a direct evaluation of the technical quality of the X-ray chest images of neonates using the Likert scale of satisfaction of three radiology specialists. We will compare the images of premature babies so that we will only use X-ray chest images of patients from the EXA PACS image storage system of the Department of Radiology of the Clinical Hospital Holy Spirit, Zagreb, which are appropriate for us by the method of imaging. Results. There is no significant correlation between the exposure parameters of the recording in relation to the body weight of the premature infant and the average technical grade of X-ray chest imaging of the premature infant regardless of the recording mode (with the incubator lid inside the incubator and without the incubator cover in the recording pad). Therefore, it is not possible to determine the ideal exposure parameters for the ideal technical quality of X-ray chest imaging of neonates. Regarding the attenuation of incubator cover radiation, we obtained the result that the incubator cover attenuates 24.19 (±0.28) %. Conclusions. With this research work we found that there is no significant correlation between the technical quality of the X-ray chest image of premature infants and the technical parameters when recording the X-ray chest image between the two groups of subjects (recorded in an incubator with an incubator lid and recorded outside the incubator in a cushion for neonates). Also, there is no significant difference between the technical parameters in relation to the body weight of the premature infant or the difference in the technical grade of the X-ray chest image of the premature infant between the groups (taken with the lid and without the incubator lid). However, we have also concluded that the incubator cap attenuates 24.19 (±0.28)%, or that the absorbed dose is 24.19% smaller if the X-ray chest imaging of the neonates was performed through the incubator cap relative to without the incubator lid.
- Subjects :
- X ray mobile units
tehnička kvaliteta
BIOMEDICINE AND HEALTHCARE. Clinical Medical Sciences
neonatologija
X ray chest
attenuation factor
BIOMEDICINA I ZDRAVSTVO. Kliničke medicinske znanosti
preterm birth
reduced dose
incubator cover
neonatology
exposure parameters
incubator
smanjena doza
RTG snimka srca i pluća
ekspozicijski parametri
poklopac inkubatora
faktor atenuacije
inkubator
nedonošče
RTG mobilni uređaj
technical quality