Back to Search Start Over

Combined Approach to Stroke Thrombectomy Using a Novel Short Flexible Aspiration Catheter with a Stent Retriever

Authors :
Remollo Friedemann, Sebastian
Terceño, Mikel
Werner, Mariano
Castaño, Carlos
Hernández-Pérez, María
Blasco, Jordi
Gimeno, Alfredo
Institut Català de la Salut
[Remollo S, Werner M, Castaño C] Department of Neurosciences, Hospital Universitari Germans Trias i Pujol, Interventional Neuroradiology Unit, Badalona, Spain. [Terceño M] Department of Neurosciences, Hospital Universitari Germans Trias i Pujol, Interventional Neuroradiology Unit, Badalona, Spain. Stroke Unit, Hospital Universitari Dr. Josep Trueta, Girona, Spain. [Hernández-Pérez M] Stroke Unit, Department of Neurosciences, Hospital Universitari Germans Trias i Pujol, Badalona, Spain. [Blasco J] Neurointerventional Department C.D.I, Hospital Clinic of Barcelona, Barcelona, Spain. [Gimeno A] Servei de Radiologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain
Vall d'Hebron Barcelona Hospital Campus
Source :
Scientia
Publication Year :
2022
Publisher :
Springer, 2022.

Abstract

Brain ischemia; Mechanical thrombectomy; Device Isquemia cerebral; Trombectomía mecánica; Dispositivo Isquèmia cerebral; Trombectomia mecànica; Dispositiu Background Large-bore aspiration catheters enabling greater flow rates and suction force for mechanical thrombectomy might improve outcomes in patients with stroke secondary to large-vessel occlusion. Complete or near-complete reperfusion after a single thrombectomy pass (first-pass effect) is associated with improved clinical outcomes. We assessed the efficacy and safety of novel MIVI Q™ aspiration catheters in combination with stent-retriever devices. Methods We retrospectively analyzed demographics, procedure characteristics, and clinical data from consecutive patients with acute anterior large-vessel occlusion treated with a combined approach using MIVI Q™ aspiration catheters and stent retrievers. Reperfusion was defined according to the modified thrombolysis in cerebral infarction (mTICI) score. Clinical outcomes were measured by the National Institute of Health Stroke Scale (NIHSS) and modified Rankin scale (mRS) scores. Results We included 52 patients (median age, 75 y IQR: 64–83); 31 (59.6%) women; 14 (26.9%) with terminal internal carotid artery occlusions, 26 (50%) middle cerebral artery (MCA) segment M1 occlusions, and 12 (23.1%) MCA segment M2 occlusions; median NIHSS score at admission was 19 (IQR: 13–22). After the first pass, 25 (48%) patients had mTICI ≥ 2c. At the end of the procedure, 47 (90.4%) had mTICI ≥ 2b and 35 (67.3%) had mTICI ≥ 2c. No serious device-related adverse events were observed. Symptomatic intracranial hemorrhage developed in 1 patient. Mean NIHSS score was 13 at 24 h and 5 at discharge. At 90 days, 24 (46.2%) patients were functionally independent (mRS 0–2). Conclusion This preliminary study found good efficacy and safety for MIVI Q™ aspiration catheters used in combination with stent-retriever devices.

Details

Language :
English
Database :
OpenAIRE
Journal :
Scientia
Accession number :
edsair.od......3991..765d865ebad4284a75dddf1afcfb2a90