Back to Search Start Over

Adaptación de cofias Co-Cr fabricadas por colado por inducción y fusión selectiva láser en CAD/CAM con escaneo clínico

Authors :
Spoljaric Muñoz, María Alejandra
Pacheco-Cahuas, María Daniela
Castillo Andamayo, Diana Esmeralda
Quintana del Solar, Martín Gilberto
Source :
Revista Estomatológica Herediana; Vol 30 No 3 (2020): July-September; 153-163, Revista Estomatológica Herediana; Vol. 30 Núm. 3 (2020): Julio-Setiembre; 153-163, Revistas-Universidad Peruana Cayetano Heredia, Universidad Peruana Cayetano Heredia, instacron:UPCH
Publication Year :
2020
Publisher :
Universidad Peruana Cayetano Heredia, 2020.

Abstract

The technique of lost wax cast by induction centrifugation (CPCI) and selective laser fusion (SLM) in design and computer- aided manufacturing (CAD / CAM) with clinical scanning, are techniques for manufacturing cobalt-chromium copings (Co-Cr), have different production processes. Objective: To evaluate, in vitro, the marginal and internal adaptation of Co- Cr metal copings made on a chamfer termination line with the CPCI and SLM technique in CAD / CAM with clinical scanning. Material and Methods: A master model of Co-Cr premolar shape was made in CAD / CAM with chamfer termination line. With a clinical scanner, the master model was scanned and 13 Co-Cr copings manufactured in SLM were obtained. Impressions were taken to obtain models in type IV plaster where 13 Co-Cr copings with CPCI technique were manufactured. The marginal and internal adaptation was evaluated using the silicone replica technique, the samples were divided into segments: vestibulo-palatal and mesio-distal and were evaluated by stereo microscope. Results: The marginal and internal discrepancies were lower for the CPCI group compared to the SLM technique in CAD / CAM with clinical scanning. In addition, the results obtained for the marginal adaptation were less than 120 μm and the internal adaptation less than 350 μm for both techniques. Conclusions: The marginal and internal adaptation in the CPCI technique compared to SLM in CAD/CAM with clinical scan were better with statistically significant difference (p

Details

Language :
Spanish; Castilian
ISSN :
22257616 and 10194355
Database :
OpenAIRE
Journal :
Revista Estomatológica Herediana; Vol 30 No 3 (2020): July-September; 153-163, Revista Estomatológica Herediana; Vol. 30 Núm. 3 (2020): Julio-Setiembre; 153-163, Revistas-Universidad Peruana Cayetano Heredia, Universidad Peruana Cayetano Heredia, instacron:UPCH
Accession number :
edsair.od......3056..89fc8db82a96fdf355c6326e308c707e