Back to Search Start Over

Precision Measurement of the Ratio <math><mrow><mi>B</mi><mo>(</mo><mi>ϒ</mi><mo>(</mo><mn>3</mn><mi>S</mi><mo>)</mo><mo>→</mo><msup><mrow><mi>τ</mi></mrow><mrow><mo>+</mo></mrow></msup><msup><mrow><mi>τ</mi></mrow><mrow><mo>−</mo></mrow></msup><mo>)</mo><mo>/</mo><mi>B</mi><mo>(</mo><mi>ϒ</mi><mo>(</mo><mn>3</mn><mi>S</mi><mo>)</mo><mo>→</mo><msup><mrow><mi>μ</mi></mrow><mrow><mo>+</mo></mrow></msup><msup><mrow><mi>μ</mi></mrow><mrow><mo>−</mo></mrow></msup><mo>)</mo></mrow></math>

Authors :
Lees, J. P.
Poireau, V.
Tisserand, V.
Grauges, E.
Palano, A.
Eigen, G.
Brown, D. N.
Kolomensky, Yu. G.
Fritsch, M.
Koch, H.
Schroeder, T.
Cheaib, R.
Hearty, C.
Mattison, T. S.
McKenna, J. A.
So, R. Y.
Blinov, V. E.
Buzykaev, A. R.
Druzhinin, V. P.
Golubev, V. B.
Kozyrev, E. A.
Kravchenko, E. A.
Onuchin, A. P.
Serednyakov, S. I.
Skovpen, Yu. I.
Solodov, E. P.
Todyshev, K. Yu.
Lankford, A. J.
Dey, B.
Gary, J. W.
Long, O.
Eisner, A. M.
Lockman, W. S.
Panduro Vazquez, W.
Chao, D. S.
Cheng, C. H.
Echenard, B.
Flood, K. T.
Hitlin, D. G.
Kim, J.
Li, Y.
Lin, D. X.
Miyashita, T. S.
Ongmongkolkul, P.
Oyang, J.
Porter, F. C.
Röhrken, M.
Huard, Z.
Meadows, B. T.
Pushpawela, B. G.
Sokoloff, M. D.
Sun, L.
Smith, J. G.
Wagner, S. R.
Bernard, D.
Verderi, M.
Bettoni, D.
Bozzi, C.
Calabrese, R.
Cibinetto, G.
Fioravanti, E.
Garzia, I.
Luppi, E.
Santoro, V.
Calcaterra, A.
de Sangro, R.
Finocchiaro, G.
Martellotti, S.
Patteri, P.
Peruzzi, I. M.
Piccolo, M.
Rotondo, M.
Zallo, A.
Passaggio, S.
Patrignani, C.
Shuve, B. J.
Lacker, H. M.
Bhuyan, B.
Mallik, U.
Chen, C.
Cochran, J.
Prell, S.
Gritsan, A. V.
Arnaud, N.
Davier, M.
Le Diberder, F.
Lutz, A. M.
Wormser, G.
Lange, D. J.
Wright, D. M.
Coleman, J. P.
Gabathuler, E.
Hutchcroft, D. E.
Payne, D. J.
Touramanis, C.
Bevan, A. J.
Di Lodovico, F.
Sacco, R.
Cowan, G.
Banerjee, Sw.
Davis, C. L.
Denig, A. G.
Gradl, W.
Griessinger, K.
Hafner, A.
Schubert, K. R.
Barlow, R. J.
Lafferty, G. D.
Cenci, R.
Jawahery, A.
Roberts, D. A.
Cowan, R.
Robertson, S. H.
Seddon, R. M.
Neri, N.
Palombo, F.
Cremaldi, L.
Godang, R.
Summers, D. J.
Taras, P.
De Nardo, G.
Sciacca, C.
Raven, G.
Jessop, C. P.
LoSecco, J. M.
Honscheid, K.
Kass, R.
Gaz, A.
Margoni, M.
Posocco, M.
Simi, G.
Simonetto, F.
Stroili, R.
Akar, S.
Ben-Haim, E.
Bomben, M.
Bonneaud, G. R.
Calderini, G.
Chauveau, J.
Marchiori, G.
Ocariz, J.
Biasini, M.
Manoni, E.
Rossi, A.
Batignani, G.
Bettarini, S.
Carpinelli, M.
Casarosa, G.
Chrzaszcz, M.
Forti, F.
Giorgi, M. A.
Lusiani, A.
Oberhof, B.
Paoloni, E.
Rama, M.
Rizzo, G.
Walsh, J. J.
Zani, L.
Smith, A. J. S.
Anulli, F.
Faccini, R.
Ferrarotto, F.
Ferroni, F.
Pilloni, A.
Piredda, G.
Bünger, C.
Dittrich, S.
Grünberg, O.
Heß, M.
Leddig, T.
Voß, C.
Waldi, R.
Adye, T.
Wilson, F. F.
Emery, S.
Vasseur, G.
Aston, D.
Cartaro, C.
Convery, M. R.
Dorfan, J.
Dunwoodie, W.
Ebert, M.
Field, R. C.
Fulsom, B. G.
Graham, M. T.
Hast, C.
Innes, W. R.
Kim, P.
Leith, D. W. G. S.
Luitz, S.
MacFarlane, D. B.
Muller, D. R.
Neal, H.
Ratcliff, B. N.
Roodman, A.
Sullivan, M. K.
Va’vra, J.
Wisniewski, W. J.
Purohit, M. V.
Wilson, J. R.
Randle-Conde, A.
Sekula, S. J.
Ahmed, H.
Bellis, M.
Burchat, P. R.
Puccio, E. M. T.
Alam, M. S.
Ernst, J. A.
Gorodeisky, R.
Guttman, N.
Peimer, D. R.
Soffer, A.
Spanier, S. M.
Ritchie, J. L.
Schwitters, R. F.
Izen, J. M.
Lou, X. C.
Bianchi, F.
De Mori, F.
Filippi, A.
Gamba, D.
Lanceri, L.
Vitale, L.
Martinez-Vidal, F.
Oyanguren, A.
Albert, J.
Beaulieu, A.
Bernlochner, F. U.
King, G. J.
Kowalewski, R.
Lueck, T.
Nugent, I. M.
Roney, J. M.
Sibidanov, A.
Sobie, R. J.
Tasneem, N.
Gershon, T. J.
Harrison, P. F.
Latham, T. E.
Prepost, R.
Wu, S. L.
Source :
Physical Review Letters
Publication Year :
2020
Publisher :
APS, 2020.

Abstract

We report on a precision measurement of the ratio Rτμϒ(3S)=B(ϒ(3S)→τ+τ−)/B(ϒ(3S)→μ+μ−) using data collected with the BABAR detector at the SLAC PEP-II e+e− collider. The measurement is based on a 28 fb−1 data sample collected at a center-of-mass energy of 10.355 GeV corresponding to a sample of 122 million ϒ(3S) mesons. The ratio is measured to be Rτμϒ(3S)=0.966&#177;0.008stat&#177;0.014syst and is in agreement with the standard model prediction of 0.9948 within 2 standard deviations. The uncertainty in Rτμϒ(3S) is almost an order of magnitude smaller than the only previous measurement.

Details

Language :
English
Database :
OpenAIRE
Journal :
Physical Review Letters
Accession number :
edsair.od......3000..d9d98b6c17f1e590c45f46b4bd86f8e7