Back to Search Start Over

Evaluation and establishment of new quality specification to immunoglobulin and albumin

Authors :
Carrillo Cabrera, Dianelys
González Farah, Ambar
Rodríguez Bernal, Josefina
Suárez Pérez, Yania
Fernández Cervera, Mirna
Veliz Rivera, Jacqueline
Publication Year :
2011

Abstract

The limits of quality specification for the parameter alcohol content, using 50 industrial batches of immunoglobulin and albumin, were calculated employing Bowker's method to get the upper specification limits for three different conditions. All the measurements of the alcohol content as impurity were performed by an enzymatic method. In addition, the behaviour of the parameter alcohol content was evaluated after the quality specification limits were estimated. The results of the follow-up phase of the 30 industrial batches were processed statistically giving best performance for the immunoglobulin. Using the control charts as tool, showed that both process were under a state of statistical control, and tend to be a capable process for immunoglobulin when Q = 99 %<br />Colegio de Farmacéuticos de la Provincia de Buenos Aires

Details

Language :
English
Database :
OpenAIRE
Accession number :
edsair.od......1329..b31360a59701449b7b89c2294470bc69