DETERMINATION OF OXYGEN CONTENT IN A COMPLEX OXIDE PrBaMn2O6-δ

Authors :
Pikulo, A. A.
Danilov, D. A.
Kudyakova, V. S.
Suntsov, A. Yu.
Publication Year :
2020
Publisher :
УрФУ, 2020.

Abstract

The determination of oxygen content in complex oxide by carrier gas hot extraction was applied. The causes of a random error were investigated. The main source was determined as the calibration procedure.