Back to Search Start Over

Estimulação ventricular bifocal no tratamento da insuficiência cardíaca com miocardiopatia dilatada

Authors :
PACHÓN MATEOS, José Carlos
VARGAS, Remy Nelson Albornoz
PACHÓN MATEOS, Enrique I.
GIMENES, Vera Márcia
PACHÓN, Maria Zélia Cunha
PACHÓN MATEOS, Juán Carlos
SANTOS FILHO, Eusébio Ramos dos
MEDEIROS, Paulo de Tarso Jorge
SILVA, Marco Aurélio Dias da
SOUSA, José Eduardo de
JATENE, Adib D.
Source :
Brazilian Journal of Cardiovascular Surgery, Volume: 15, Issue: 1, Pages: 44-54, Published: MAR 2000
Publication Year :
2000
Publisher :
Sociedade Brasileira de Cirurgia Cardiovascular, 2000.

Abstract

INTRODUÇÃO: O alargamento do QRS pela estimulação ventricular artificial (EVa) convencional prejudica a contratilidade cardíaca e a função mitral. OBJETIVO: Propôr um modo alternativo de EVa com QRS mais estreito, com 2 eletrodos em ventrículo direito(VD) e testá-lo frente à EVa convencional. CASUÍSTICA E MÉTODOS: Cinco pacientes com indicação para implantação de marcapasso definitivo(MP), 4M/1F, idade média de 52,2 anos, portadores de ICC (III/IV) por miocardiopatia dilatada (Chagas 4, Indeterminada 1), AC 3+/4+, FA crônica com BAV, foram submetidos a implante de MP endocárdico com 2 eletrodos em VD, o primeiro na área do feixe de His (septal) e o segundo, convencional, na ponta do VD. O gerador foi Biotronik Dromos DR (único com AV mínimo de 15ms). O eletrodo septal foi conectado à saída atrial e o de ponta à saída ventricular. Após 2 semanas, os pacientes foram avaliados ecocardiograficamente, na mesma sessão, em 3 modos de estimulação na mesma freqüência: modo "AAI" (septal), modo VVI (convencional) e modo "DDT" com intervalo AV=15ms (estimulação bifocal no VD quase simultânea). RESULTADOS: As médias dos parâmetros estudados estão na tabela abaixo: CONCLUSÃO: Sob o ponto de vista ecocardiográfico, a comparação imediata no mesmo paciente dos 3 modos de estimulação revelou: 1-O modo convencional foi o de pior rendimento hemodinâmico; 2-O modo bifocal mostrou o melhor resultado com aumento médio da FE em 6,8% e do DC em 0,6 l/min, redução média do AE em 7,5 cm2, redução média da área de refluxo mitral em 7,6 cm2 e redução média na duração do QRS em 61 ms, (p < 0,03), sendo a melhor EVa na miocardiopatia dilatada com insuficiência cardíaca, insuficiência mitral funcional e indicação de MP. BACKGROUND: Widening of QRS by ventricular conventional pacing (CP) impairs ventricular contractility and mitral performance. PURPOSE: To study an alternative mode of cardiac stimulation with narrower QRS, using 2 leads in the right ventricle and to test it, compared to CP. MATERIAL AND METHODS: 5 dilated cardiomyopathy patients (3 Chagas´ disease, 2 unknown) with cardiac failure (NYHA III/4) and pacemaker (PM) indication, 4 male/1 female, mean age 52.2. years, cardiac shape 3+/4+, chronic AF with AVB, were submitted to endocardial PM implants with 2 right ventricular leads. The first in the His bundle area (septal) and the second, conventional, in the right ventricular apex. The generator was Biotronik Dromos DR (the short programmable AV = 15ms). The septal lead was connected to the atrial outflow and the one of the apex to the ventricular exit. After 2 weeks, they were studied by echocardiogram, in 3 stimulation modes in the same session with same cardiac rate: mode "AAI" (septal), mode VVI (conventional) and mode "DDT" with AV interval=15ms (almost simultaneous bifocal stimulation). RESULTS: The averages of the parameters studied were: CONCLUSION: The echocardiographic evaluation for the immediate comparison in the same patient with 3 stimulation modes, revealed: 1. The conventional mode showed the worse hemodynamic performance; 2. the bifocal mode showed the best result with mean increase of the EF of 6.8% and of CO in 0.6 l/min, mean reduction of LA in 7.5 cm2, mean reduction of the area of mitral regurgitation in 7.6 cm2 and mean reduction in the QRS duration of 61ms, (p < 0.03). It was the best stimulation in cardiomyopathy with heart failure, functional mitral regurgitation and pacemaker indication.

Details

Language :
Portuguese
Database :
OpenAIRE
Journal :
Brazilian Journal of Cardiovascular Surgery, Volume: 15, Issue: 1, Pages: 44-54, Published: MAR 2000
Accession number :
edsair.od.......608..2d779ceaad09d44818d2314fdf684225