Back to Search Start Over

F-18-labeled anti-human CD20 cys-diabody for same-day immunoPET in a model of aggressive B cell lymphoma in human CD20 transgenic mice

Authors :
Zettlitz, Kirstin A
Tavare, Richard
Tsai, Wen-Ting K
Yamada, Reiko E
Ha, Noel S
Collins, Jeffrey
van Dam, R Michael
Timmerman, John M
Wu, Anna M
Source :
Zettlitz, Kirstin A; Tavare, Richard; Tsai, Wen-Ting K; Yamada, Reiko E; Ha, Noel S; Collins, Jeffrey; et al.(2019). F-18-labeled anti-human CD20 cys-diabody for same-day immunoPET in a model of aggressive B cell lymphoma in human CD20 transgenic mice. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 46(2), 489-500. doi: 10.1007/s00259-018-4214-x. Lawrence Berkeley National Laboratory: Retrieved from: http://www.escholarship.org/uc/item/0gt2g894
Publication Year :
2019
Publisher :
eScholarship, University of California, 2019.

Abstract

PURPOSE:Metabolic imaging using [18F]FDG is the current standard for clinical PET; however, some malignancies (e.g., indolent lymphomas) show low avidity for FDG. The majority of B cell lymphomas express CD20, making it a valuable target both for antibody-based therapy and imaging. We previously developed PET tracers based on the humanised anti-CD20 antibody obinutuzumab (GA101). Preclinical studies showed that the smallest bivalent fragment, the cys-diabody (GAcDb, 54.5 kDa) with a peak uptake at 1-2 h post-injection and a biological half-life of 2-5 h, is compatible with short-lived positron emitters such as fluorine-18 (18F, t1/2 110 min), enabling same-day imaging. METHODS:GAcDb was radiolabeled using amine-reactive N-succinimidyl 4-[18F]-fluorobenzoate ([18F]SFB), or thiol-reactive N-[2-(4-[18F]-fluorobenzamido)ethyl]maleimide ([18F]FBEM) for site-specific conjugation to C-terminal cysteine residues. Both tracers were used for immunoPET imaging of the B cell compartment in human CD20 transgenic mice (hCD20TM). [18F]FB-GAcDb immunoPET was further evaluated in a disseminated lymphoma (A20-hCD20) syngeneic for hCD20TM and compared to [18F]FDG PET. Tracer uptake was confirmed by ex vivo biodistribution. RESULTS:The GAcDb was successfully 18F-radiolabeled using two different conjugation methods resulting in similar specific activities and without impairing immunoreactivity. Both tracers ([18F]FB-GAcDb and [18F]FBEM-GAcDb) specifically target human CD20-expressing B cells in transgenic mice. Fast blood clearance results in high contrast PET images as early as 1 h post injection enabling same-day imaging. [18F]FB-GAcDb immunoPET detects disseminated lymphoma disease in the context of normal tissue expression of hCD20, with comparable sensitivity as [18F]FDG PET but with added specificity for the therapeutic target. CONCLUSIONS:[18F]FB-GAcDb and [18F]FBEM-GAcDb could monitor normal B cells and B cell malignancies non-invasively and quantitatively in vivo. In contrast to [18F]FDG PET, immunoPET provides not only information about the extent of disease but also about presence and localisation of the therapeutic target.

Details

Language :
English
Database :
OpenAIRE
Journal :
Zettlitz, Kirstin A; Tavare, Richard; Tsai, Wen-Ting K; Yamada, Reiko E; Ha, Noel S; Collins, Jeffrey; et al.(2019). F-18-labeled anti-human CD20 cys-diabody for same-day immunoPET in a model of aggressive B cell lymphoma in human CD20 transgenic mice. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 46(2), 489-500. doi: 10.1007/s00259-018-4214-x. Lawrence Berkeley National Laboratory: Retrieved from: http://www.escholarship.org/uc/item/0gt2g894
Accession number :
edsair.od.......325..f3b01575f06ff00d7742fc4dc315dc7c