Portable lactate analyzer for measuring lactate in cerebrospinal fluid (CSF) and plasma - Method-comparison evaluations

Authors :
de Almeida, SM
Marquie-Beck, J
Bhatt, A
Letendre, S
McCutchan, JA
Ellis, RJ
Heaton, RK
Grant, I
Atkinson, JH
Marcotte, TD
Sherman, M
Best, B
Schrier, R
Alexander, T
Rosario, D
Woods, SP
Cherner, M
Moore, DJ
Dawson, M
Fennema-Notestine, C
Jernigan, T
Buchsbaum, MS
Hesselink, J
Archibald, SL
Brown, G
Buxton, R
Dale, A
Liu, T
Masliah, E
Achim, C
Everall, I
Smith, DM
Richman, D
Lipton, S
Gamst, AC
Cushman, C
Abramson, I
Vaida, F
Deutsch, R
Umlauf, A
Kao, C
Source :
de Almeida, SM; Marquie-Beck, J; Bhatt, A; Letendre, S; McCutchan, JA; Ellis, RJ; et al.(2014). Portable lactate analyzer for measuring lactate in cerebrospinal fluid (CSF) and plasma-Method-comparison evaluations. Arquivos de Neuro-Psiquiatria, 72(7), 500-505. doi: 10.1590/0004-282X20140076. UC San Diego: Retrieved from: http://www.escholarship.org/uc/item/3zc2w0xc
Publication Year :
2014
Publisher :
eScholarship, University of California, 2014.

Abstract

Increased plasma lactate levels can indicate the presence of metabolic disorders in HIV infected individuals. Objective: To determine whether a portable analyzer is valid for measuring cerebrospinal fluid (CSF) and plasma lactate levels in HIV infected individuals. Method: CSF and plasma were collected from 178 subjects. Samples tested by the Accutrend® portable analyzer were compared to those tested by a reference device (SYNCHRON LX® 20). Results: The portable analyzer had in plasma sensitivity of 0.95 and specificity 0.87. For CSF the specificity was 0.95; the sensitivity 0.33; the negative predictive value was 95% and the positive predictive value 33%. Conclusions: These findings support the validity of the portable analyzer in measuring lactate concentrations in CSF that fall within the normal range. The relatively poor positive predictive value indicates that a result above the reference range may represent a "false positive test", and should be confirmed by the reference device before concluding abnormality.

Details

Language :
English
Database :
OpenAIRE
Journal :
de Almeida, SM; Marquie-Beck, J; Bhatt, A; Letendre, S; McCutchan, JA; Ellis, RJ; et al.(2014). Portable lactate analyzer for measuring lactate in cerebrospinal fluid (CSF) and plasma-Method-comparison evaluations. Arquivos de Neuro-Psiquiatria, 72(7), 500-505. doi: 10.1590/0004-282X20140076. UC San Diego: Retrieved from: http://www.escholarship.org/uc/item/3zc2w0xc