Back to Search Start Over

The ATLAS Liquid Argon Forward Calorimeter: Electrode Uniformity

Authors :
Bélanger, G
Coley, K
Embry, T
Khakzad, M
Krieger, P
Orr, R
Neuheimer, E
Mes, H
Oakham, G
Rutherfoord, J
Savin, A
Shaver, L
Starr, M
Strickland, V
Vincent, K
Publication Year :
2005

Abstract

The mechanical precision of the electrode gaps contributes to the uniformity of response of a liquid argon calorimeter. The electrode capacitance is a sensitive measure of the gap. The capacitance of every electrode in every ATLAS Forward Calorimeter module has been measured giving an rms deviation ranging from 0.8% to 1.7% depending on the module. In concert with the measurements, we have also calculated the capacitance using measurements of the electrode dimensions. The calculated and measured electrode capacitances show good agreement.

Details

Language :
English
Database :
OpenAIRE
Accession number :
edsair.od........65..82794f7542ad0a0ae4f63bd0dbfa28a0