Back to Search Start Over

Operational modelling of preventive maintenance of a production plant

Authors :
Christer, A.H.
Wang, Wenbin
Baker, R.D.
Sharp, J.
Wyant, T.
Martin, H.H.
Operations Planning Acc. & Control
Source :
New developments in maintenance, 217-233, STARTPAGE=217;ENDPAGE=233;TITLE=New developments in maintenance
Publication Year :
1995
Publisher :
Moret Ernst & Young, 1995.

Abstract

In this paper we describe a case study carried out at a local company which manufactures copper products. The study addresses the imptementing of Planned Prevenlive Maintenance (P M) of an Extrusion Press, a key capita/ machine in the company. Using the Delay Time Modelling Technique, the model parameter values are estimatedfrom subjective data obtained through a questionnaire survey, and a goodness of fit test is proposed to assess the model fit. As aresult of the model test, revised parameter values are obtained in termsof the "best" model fit. Based upon the results of data analysis and delay time modelling, improved P M policy and procedures have been proposed to increase the effectiveness and efficiency of PM These proposals have been generally accepted by the company. The results are highlighted

Details

Language :
English
Database :
OpenAIRE
Journal :
New developments in maintenance, 217-233, STARTPAGE=217;ENDPAGE=233;TITLE=New developments in maintenance
Accession number :
edsair.narcis........365364369c2cb1a66e7cd426e101987b