Back to Search
Start Over
Effect of conservation method on ear mechanics for the same specimen
- Source :
- Graf, Lukas; Arnold, Andreas; Roushan, Kourosh; Honegger, Flurin; Müller-Gerbl, Magdalena; Stieger, Christof (2021). Effect of conservation method on ear mechanics for the same specimen. Hearing research, 401, p. 108152. Elsevier 10.1016/j.heares.2020.108152
- Publication Year :
- 2021
- Publisher :
- Elsevier, 2021.
-
Abstract
- BACKGROUND AND AIMS As an alternative to fresh temporal bones, Thiel conserved specimens can be used in the study of ear mechanics. Conserved temporal bones do not decay, permit long-term experiments and overcome problems with limited access to fresh (frozen) temporal bones. Air conduction motion of the tympanic membrane (TM), stapes (ST) and round window (RW) in Thiel specimens is similar to that of fresh specimens according to reports in the literature. Our study compares this motion directly before and after conservation for the same specimens. METHODS The magnitude of motion of TM, ST and RW elicited by acoustic stimulation via the external auditory canal was measured using single point laser Doppler vibrometry (LDV) accessed through a posterior tympanotomy. For the initial measurements (10 ears), fresh frozen whole heads were thawed for at least 24��h. Afterwards, the entire whole heads were embalmed according to the Thiel embalming method and measurements were repeated 3 and 12 months later. RESULTS The magnitudes of TM, ST and RW motion before and after Thiel conservation differed maximally 10��dB on average. A significant increase in TM motion was observed at low frequencies only after long term conservation (12 months). ST motions decreased significantly between 161 and 5300��Hz after 3 months of Thiel conservation. Over the same time period RW motions decreased significantly between 100 and 161��Hz and 489-788��Hz. The ST and RW motions across all measured frequencies were lower after 3 months by 5.7��dB and 7.1��dB, respectively, without further changes after 12 months of conservation. The mean phase shift between ST and RW motion was only 2.1�� for frequencies below 450��Hz. DISCUSSION AND CONCLUSION Thiel embalming changes motion of TM after long term conservation. ST and RW motion changed mainly after short term conservation. The phase shifts close to 180�� between ST and RW motion indicates that the cochlea was still filled with liquid without air bubbles. The results show that Thiel conserved specimens can be used as an alternative model to fresh frozen preparations with some limitations when studying mechanics of the normal human ear, for example, in implant design.
- Subjects :
- 0301 basic medicine
Human ear
610 Medicine & health
Limited access
03 medical and health sciences
0302 clinical medicine
Incus
medicine
Humans
Mathematics
Stapes
Embalming
Round window
Air conduction
Temporal Bone
Mechanics
Laser Doppler velocimetry
Sensory Systems
Ossicular Prosthesis
030104 developmental biology
medicine.anatomical_structure
Acoustic Stimulation
Round Window, Ear
Fresh frozen
Single point
030217 neurology & neurosurgery
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- Graf, Lukas; Arnold, Andreas; Roushan, Kourosh; Honegger, Flurin; Müller-Gerbl, Magdalena; Stieger, Christof (2021). Effect of conservation method on ear mechanics for the same specimen. Hearing research, 401, p. 108152. Elsevier 10.1016/j.heares.2020.108152 <http://dx.doi.org/10.1016/j.heares.2020.108152>
- Accession number :
- edsair.doi.dedup.....ff33167095f1f251eafbeec0563ad822
- Full Text :
- https://doi.org/10.1016/j.heares.2020.108152