Back to Search Start Over

Design Guidelines for a Double Scattering Compton Camera for Prompt-gamma Imaging During Ion Beam Therapy: A Monte Carlo Simulation Study

Authors :
A.H. Walenta
M.-H. Richard
M. Chevallier
F. Le Foulher
Denis Dauvergne
Jean Michel Létang
F. Roellinghoff
Nicolas Freud
Etienne Testa
Gerard Montarou
P. Henriquet
Cédric Ray
M. Testa
Institut de Physique Nucléaire de Lyon (IPNL)
Université Claude Bernard Lyon 1 (UCBL)
Université de Lyon-Université de Lyon-Institut National de Physique Nucléaire et de Physique des Particules du CNRS (IN2P3)-Centre National de la Recherche Scientifique (CNRS)
Controle Non Destructif par Rayonnements Ionisants (CNDRI)
Institut National des Sciences Appliquées de Lyon (INSA Lyon)
Université de Lyon-Institut National des Sciences Appliquées (INSA)-Université de Lyon-Institut National des Sciences Appliquées (INSA)
CAS-PHABIO
Université de Lyon-Université de Lyon-Institut National de Physique Nucléaire et de Physique des Particules du CNRS (IN2P3)-Centre National de la Recherche Scientifique (CNRS)-Université Claude Bernard Lyon 1 (UCBL)
Laboratoire de Physique Corpusculaire - Clermont-Ferrand (LPC)
Université Blaise Pascal - Clermont-Ferrand 2 (UBP)-Institut National de Physique Nucléaire et de Physique des Particules du CNRS (IN2P3)-Centre National de la Recherche Scientifique (CNRS)
Centre National de la Recherche Scientifique (CNRS)-Université Claude Bernard Lyon 1 (UCBL)
Université de Lyon-Université de Lyon-Institut National de Physique Nucléaire et de Physique des Particules du CNRS (IN2P3)
Source :
IEEE Transactions on Nuclear Science, IEEE Transactions on Nuclear Science, 2010, 58, pp.87-94. ⟨10.1109/TNS.2010.2076303⟩, IEEE Transactions on Nuclear Science, Institute of Electrical and Electronics Engineers, 2010, 58, pp.87-94. ⟨10.1109/TNS.2010.2076303⟩
Publication Year :
2010
Publisher :
HAL CCSD, 2010.

Abstract

In hadrontherapy in order to fully take advantage of the assets of the ion irradiation, the position of the Bragg peak has to be monitored accurately. Here, we investigate a monitoring method relying on the detection in real time of the prompt gamma emitted quasi instantaneously during the nuclear fragmentation processes. Our detection system combines a beam hodoscope and a double scattering Compton camera. The prompt-gamma emission points are reconstructed by intersecting the ion trajectories given by the hodoscope and the Compton cones reconstructed with the camera. We propose here to study in terms of point spread function and efficiency the theoretical feasibility of the emission points reconstruction with our set-up in the case of a photon point source in air. First we analyze the nature of all the interactions which are likely to produce an energy deposit in the three detectors of the camera. It is underlined that upper energy thresholds in both scatter detectors are required in order to select mainly Compton events (one Compton interaction in each scatter detector and one interaction in the absorber detector). Then, we study the influence of various parameters such as the photon energy and the inter-detector distances on the Compton camera response. These studies are carried out by means of Geant4 simulations. We use a source with a spectrum corresponding to the prompt-gamma spectrum emitted during the carbon ion irradiation of a water phantom. In the current configuration, the spatial resolution of the Compton camera is about 6 mm (Full Width at Half Maximum) and the detection efficiency 10^{-5}. Finally, provided the detection efficiency is increased, the clinical applicability of our system is considered.

Details

Language :
English
ISSN :
00189499
Database :
OpenAIRE
Journal :
IEEE Transactions on Nuclear Science, IEEE Transactions on Nuclear Science, 2010, 58, pp.87-94. ⟨10.1109/TNS.2010.2076303⟩, IEEE Transactions on Nuclear Science, Institute of Electrical and Electronics Engineers, 2010, 58, pp.87-94. ⟨10.1109/TNS.2010.2076303⟩
Accession number :
edsair.doi.dedup.....fefc9da6ea22c5fa83dbc1b32228d175
Full Text :
https://doi.org/10.1109/TNS.2010.2076303⟩