Back to Search Start Over

Detection limit of 89Zr-labeled T cells for cellular tracking: an in vitro imaging approach using clinical PET/CT and PET/MRI

Authors :
Matthew Cleveland
Nick Bird
Doreen Lau
Luigi Aloj
Neel Patel
Joanne L. Jones
Tim D. Fryer
Laura M. Lechermann
Ferdia A. Gallagher
Lorna B. Jarvis
Bala Attili
Franklin I. Aigbirhio
Bristi Basu
Roido Manavaki
Lechermann, Laura M [0000-0002-2742-6269]
Apollo - University of Cambridge Repository
Source :
EJNMMI Research, Vol 10, Iss 1, Pp 1-12 (2020)
Publication Year :
2020
Publisher :
SpringerOpen, 2020.

Abstract

Purpose Tracking cells in vivo using imaging can provide non-invasive information to understand the pharmacology, efficacy, and safety of novel cell therapies. Zirconium-89 (t1/2 = 78.4 h) has recently been used to synthesize [89Zr]Zr(oxinate)4 for cell tracking using positron emission tomography (PET). This work presents an in vitro approach to estimate the detection limit for in vivo PET imaging of Jurkat T cells directly labeled with [89Zr]Zr(oxinate)4 utilizing clinical PET/CT and PET/MRI. Methods Jurkat T cells were labeled with varying concentrations of [89Zr]Zr(oxinate)4 to generate different cell-specific activities (0.43–31.91 kBq/106 cells). Different concentrations of labeled cell suspensions (104, 105, and 106 cells) were seeded on 6-well plates and into a 3 × 3 cubic-well plate with 1 cm3 cubic wells as a gel matrix. Plates were imaged on clinical PET/CT and PET/MRI scanners for 30 min. The total activity in each well was determined by drawing volumes of interest over each well on PET images. The total cell-associated activity was measured using a well counter and correlated with imaging data. Simulations for non-specific signal were performed to model the effect of non-specific radioactivity on detection. Results Using this in vitro model, the lowest cell number that could be visualized on 6-well plate images was 6.8 × 104, when the specific activity was 27.8 kBq/106 cells. For the 3 × 3 cubic-well, a plate of 3.3 × 104 cells could be detected on images with a specific activity of 15.4 kBq/106 cells. Conclusion The results show the feasibility of detecting [89Zr]Zr(oxinate)4-labeled Jurkat T cells on clinical PET systems. The results provide a best-case scenario, as in vivo detection using PET/CT or PET/MRI will be affected by cell number, specific activity per cell, the density of cells within the target volume, and non-specific signal. This work has important implications for cell labeling studies in patients, particularly when using radiosensitive cells (e.g., T cells), which require detection of low cell numbers while minimizing radiation dose per cell.

Details

Language :
English
Volume :
10
Issue :
1
Database :
OpenAIRE
Journal :
EJNMMI Research
Accession number :