Reply to 'Letter to the editor: ‘Assessment of flow-mediated dilation in humans: a methodological and physiological guideline''
- Source :
- American Journal of Physiology : Heart and Circulatory Physiology, 300, pp. H713-H713, American Journal of Physiology : Heart and Circulatory Physiology, 300, H713-H713
- Publication Year :
- 2011
- Publisher :
- American Physiological Society, 2011.
-
Abstract
- reply: We would like to thank Mc Loughlin and Mc Loughlin (4a) for their response and for bringing attention to the appropriate selection of transducer operating frequency for flow-mediated dilation investigations. We agree that employing a transducer with a higher central frequency (i.e., 12 MHz) will yield a greater detail resolution in the axial plane when interrogating vessels such as the brachial artery, and this would provide a greater sensitivity in detecting small changes in flow-evoked vasodilatation. However, in our review (8), we discussed not only the brachial artery but also the common femoral (9), profunda femoris (12), superficial femoral (1, 2, 10, 12), popliteal (5, 6, 11), and posterior tibial (3, 7) arteries. When these lower-limb vessels are insonated at an optimal region in terms of flow conditions, for example, at a distance where entrance effects are minimized, the artery depth is often greater than that expected for a typical brachial artery. Given that the average attenuation coefficient is 0.5 dB·cm−1·MHz−1 (4), there is considerable degradation of image quality when employing a high-frequency probe while imaging a deeper lying vessel. This can render the image unusable when combined with automated analysis software. The subsequent trade-off between detail resolution and depth penetration is a further consideration for researchers when performing flow-mediated dilation investigations; however, the minimum transducer recommended is 7.5 MHz for all peripheral arteries so as to maintain adequate detail resolution. Certainly, we advocate the use of higher transducer frequencies (i.e., 12 MHz) when investigating more superficial vessels such as the brachial and radial arteries.
- Subjects :
- medicine.medical_specialty
Physiology
business.industry
Image quality
Flow mediated dilation
Surgery
medicine.anatomical_structure
Transducer
Physiology (medical)
medicine.artery
Analysis software
Medicine
Dilation (morphology)
Center frequency
Brachial artery
Cardiovascular diseases Health aging / healthy living [NCEBP 14]
Cardiology and Cardiovascular Medicine
business
Letters to the Editor
Artery
Biomedical engineering
Subjects
Details
- Language :
- English
- ISSN :
- 03636135
- Database :
- OpenAIRE
- Journal :
- American Journal of Physiology : Heart and Circulatory Physiology, 300, pp. H713-H713, American Journal of Physiology : Heart and Circulatory Physiology, 300, H713-H713
- Accession number :
- edsair.doi.dedup.....fcead3f5e4742590315633b0021fd547