Back to Search Start Over

Consensus Recommendation for Mouse Models of Ocular Hypertension to Study Aqueous Humor Outflow and Its Mechanisms

Authors :
Colleen M. McDowell
Krishnakumar Kizhatil
Michael H. Elliott
Darryl R. Overby
Joseph van Batenburg-Sherwood
J. Cameron Millar
Markus H. Kuehn
Gulab Zode
Ted S. Acott
Michael G. Anderson
Sanjoy K. Bhattacharya
Jacques A. Bertrand
Terete Borras
Diane E. Bovenkamp
Lin Cheng
John Danias
Michael Lucio De Ieso
Yiqin Du
Jennifer A. Faralli
Rudolf Fuchshofer
Preethi S. Ganapathy
Haiyan Gong
Samuel Herberg
Humberto Hernandez
Peter Humphries
Simon W. M. John
Paul L. Kaufman
Kate E. Keller
Mary J. Kelley
Ruth A. Kelly
David Krizaj
Ajay Kumar
Brian C. Leonard
Raquel L. Lieberman
Paloma Liton
Yutao Liu
Katy C. Liu
Navita N. Lopez
Weiming Mao
Timur Mavlyutov
Fiona McDonnell
Gillian J. McLellan
Philip Mzyk
Andrews Nartey
Louis R. Pasquale
Gaurang C. Patel
Padmanabhan P. Pattabiraman
Donna M. Peters
Vijaykrishna Raghunathan
Ponugoti Vasantha Rao
Naga Rayana
Urmimala Raychaudhuri
Ester Reina-Torres
Ruiyi Ren
Douglas Rhee
Uttio Roy Chowdhury
John R. Samples
E. Griffen Samples
Najam Sharif
Joel S. Schuman
Val C. Sheffield
Cooper H. Stevenson
Avinash Soundararajan
Preeti Subramanian
Chenna Kesavulu Sugali
Yang Sun
Carol B. Toris
Karen Y. Torrejon
Amir Vahabikashi
Janice A. Vranka
Ting Wang
Colin E. Willoughby
Chen Xin
Hongmin Yun
Hao F. Zhang
Michael P. Fautsch
Ernst R. Tamm
Abbot F. Clark
C. Ross Ethier
W. Daniel Stamer
Source :
Investigative ophthalmology & visual science, vol 63, iss 2
Publication Year :
2022
Publisher :
Association for Research in Vision and Ophthalmology (ARVO), 2022.

Abstract

Due to their similarities in anatomy, physiology, and pharmacology to humans, mice are a valuable model system to study the generation and mechanisms modulating conventional outflow resistance and thus intraocular pressure. In addition, mouse models are critical for understanding the complex nature of conventional outflow homeostasis and dysfunction that results in ocular hypertension. In this review, we describe a set of minimum acceptable standards for developing, characterizing, and utilizing mouse models of open-angle ocular hypertension. We expect that this set of standard practices will increase scientific rigor when using mouse models and will better enable researchers to replicate and build upon previous findings.

Details

ISSN :
15525783
Volume :
63
Database :
OpenAIRE
Journal :
Investigative Opthalmology & Visual Science
Accession number :
edsair.doi.dedup.....fc2366dca55a396f9cef10de74cc76d5
Full Text :
https://doi.org/10.1167/iovs.63.2.12