Back to Search
Start Over
Tear break-up time for tear film evaluation: Are moistening solutions interchangeable?
- Source :
- UPCommons. Portal del coneixement obert de la UPC, Universitat Politècnica de Catalunya (UPC), Recercat. Dipósit de la Recerca de Catalunya, instname
- Publication Year :
- 2015
-
Abstract
- Purpose: It was the main purpose of this study to investigate the influence of the moistening solution on TBUT measurements in an asymptomatic population.; Methods: An online survey was employed to determine the compliance of Spanish eye care practitioners with the recommended normalized procedure to administer TBUT. For the purpose of examining the clinical relevance of discrepancies from the recommended procedure, a randomized, double-masked, bilateral study was designed in which a micropipette was used to moisten fluorescein strips with a controlled volume of six different solutions, commonly available in the contact lens office, and TBUT was measured in 58 non-dry eye (OSDI < 15) subjects (age from 19 to 32 years).; Results: Results from the online survey revealed that 64% of Spanish practitioners frequently use (or have used) different solutions to moisten fluorescein strips during TBUT assessment. Statistically significant differences in TBUT values were found between the various solutions as a whole (chi(2) = 198.384, p < 0.001), as well as between all solutions when explored pair-wise (all p < 0.001), except for the two saline solutions.; Conclusions: The present findings support the relevance of selecting the appropriate solution when conducting TBUT for the evaluation of the tear film. Deviations from the recommended procedure may result in misdiagnosis of dry eye and unnecessary patient referral. (C) 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
- Subjects :
- Adult
Male
Dacriologia
Population
SUBCOMMITTEE
Dry eye
Moistening solution
Diagnostic Techniques, Ophthalmological
Eye care
Dry eye syndromes
Tear film
Young Adult
Patient referral
Ulls -- Malalties i defectes
Humans
Medicine
education
education.field_of_study
RESIDENCE TIMES
Sodium fluorescein
business.industry
VALUES
WORKSHOP
SODIUM HYALURONATE
General Medicine
Tear break-up time
Contact lens
Ophthalmology
Tear break up time
Health Care Surveys
Tears
Practice Guidelines as Topic
Eye--Diseases
TESTS
Optometry
Dry Eye Syndromes
Female
Fluorescein
Ciències de la visió [Àrees temàtiques de la UPC]
Guideline Adherence
Ophthalmic Solutions
Tear film evaluation
DRY EYE DISEASE
business
REPEATABILITY
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- UPCommons. Portal del coneixement obert de la UPC, Universitat Politècnica de Catalunya (UPC), Recercat. Dipósit de la Recerca de Catalunya, instname
- Accession number :
- edsair.doi.dedup.....fb20b20009a48852592ead23567daa89