Abstract
- A low modulation factor (MF) maintaining a good dose distribution contributes to the shortening of the delivery time and efficiency of the treatment plan in helical tomotherapy. The purpose of this study was to reduce the delivery time using initial values and the upper limit values of MF. First, patients with head and neck cancer (293 cases) or prostate cancer (181 cases) treated between June 2011 and July 2015 were included in the analysis of MF values. The initial MF value (MF initial) was defined as the average MF actual value, and the upper limit of the MF value (MFUL) was defined according the following equation: MFUL = 2 × standard deviation of MF actual value + the average MF actual Next, a treatment plan was designed for patients with head and neck cancer (62 cases) and prostate cancer (13 cases) treated between December 2015 and June 2016. The average MF actual value for the nasopharynx, oropharynx, hypopharynx, and prostate cases decreased from 2.1 to 1.9 (p = 0.0006), 1.9 to 1.6 (p < 0.0001), 2.0 to 1.7 (p < 0.0001), and 1.8 to 1.6 (p = 0.0004) by adapting the MF initial and the MFUL values, respectively. The average delivery time for the nasopharynx, oropharynx, hypopharynx, and prostate cases also decreased from 19.9 s cm−1 to 16.7 s cm−1 (p < 0.0001), 15.0 s cm−1 to 13.9 s cm−1 (p = 0.025), 15.1 s cm−1 to 13.8 s cm−1 (p = 0.015), and 23.6 s cm−1 to 16.9 s cm−1 (p = 0.008) respectively. The delivery time was shortened by the adaptation of MF initial and MFUL values with a reduction in the average MF actual for head and neck cancer and prostate cancer cases.
- Subjects :
- Male
medicine.medical_specialty
Time Factors
medicine.medical_treatment
Dose distribution
Tomotherapy
030218 nuclear medicine & medical imaging
head and neck
03 medical and health sciences
Prostate cancer
0302 clinical medicine
Treatment plan
Prostate
87.53.Tf
medicine
Radiation Oncology Physics
Humans
Radiology, Nuclear Medicine and imaging
Head and neck
Instrumentation
prostate
Radiation
business.industry
Radiotherapy Planning, Computer-Assisted
Head and neck cancer
helical tomotherapy
Prostatic Neoplasms
Radiotherapy Dosage
delivery time
medicine.disease
Surgery
Modulation factor
medicine.anatomical_structure
Head and Neck Neoplasms
030220 oncology & carcinogenesis
Radiotherapy, Intensity-Modulated
business
Nuclear medicine
Tomography, Spiral Computed
modulation factor
Subjects
Details
- ISSN :
- 15269914
- Volume :
- 18
- Database :
- OpenAIRE
- Journal :
- Journal of Applied Clinical Medical Physics
- Accession number :
- edsair.doi.dedup.....fad6d2b1f63f166b201e5f036b14805d