Back to Search Start Over

Impact of a multileaf collimator on treatment morbidity in localized carcinoma of the prostate

Authors :
Sharon Hummel
Peter Wootton
Thomas W. Griffin
Jon Jacky
George E. Laramore
Karen L. Lindsley
Mary Austin-Seymour
Richard J. Caplan
Kenneth J. Russell
Source :
International Journal of Radiation Oncology*Biology*Physics. 30:1065-1071
Publication Year :
1994
Publisher :
Elsevier BV, 1994.

Abstract

Purpose: To evaluate the effectiveness of variable multileaf collimation, three-dimensional treatment planning, and computer-controlled conformal radiation therapy of prostate cancer. Methods and Materials: Two hundred and forty-five patients with locally advanced prostate cancer have completed treatment over a 9-year time span using a multileaf collimator and conformal treatment techniques on the University of Washington cyclotron. All patients had three-dimensional treatment planning with computed tomography scans in the treatment position, and had treatment fields individually shaped to the target volume with a continuously variable multileaf collimator. Treatment was delivered under computer control with network transfer of the multileaf collimator settings from the treatment planning computer to the cyclotron control system. Results: The multileaf collimator combined with three-dimensional treatment planning results in elegant dose distributions. These neutron dose distributions resulted in a reduced local/regional tumor failure rate with no increase in complications when compared to control treatment with photons in a randomized trial. Neutron treatment delivered at other institutions without conformal beam shaping resulted in the same improvement in local-regional tumor control rates, but was associated with a significantly higher normal tissue complication rate than seen with conformal neutron beam delivery techniques (grade 3 and 4 cumulative late normal tissue toxicity rates of 39% vs. 10%, p = 0.0007). Conclusions: Conformal treatment of prostate cancer using a multileaf collimated neutron beam results in increased local/regional tumor control rates with low normal tissue toxicities. This experience is directly applicable to the conformal treatment of prostate cancer with photons.

Details

ISSN :
03603016
Volume :
30
Database :
OpenAIRE
Journal :
International Journal of Radiation Oncology*Biology*Physics
Accession number :
edsair.doi.dedup.....f989667f48557f868e68c68b5de11451
Full Text :
https://doi.org/10.1016/0360-3016(94)90311-5