Performance of intermittently scanned continuous glucose monitoring systems in people with type 1 diabetes: A pooled analysis
- Source :
- Diabetes, obesity and metabolism
- Publication Year :
- 2021
- Publisher :
- Wiley, 2021.
-
Abstract
- Aims: To conduct a pooled analysis to assess the performance of intermittently scanned continuous glucose monitoring (isCGM) in association with the rate of change in sensor glucose in a cohort of children, adolescents, and adults with type 1 diabetes. Material and methods: In this pooled analysis, isCGM system accuracy was assessed depending on the rate of change in sensor glucose. Clinical studies that have been investigating isCGM accuracy against blood glucose, accompanied with collection time points were included in this analysis. isCGM performance was assessed by means of median absolute relative difference (MedARD), Parkes error grid (PEG) and Bland-Altman plot analyses. Results: Twelve studies comprising 311 participants were included, with a total of 15 837 paired measurements. The overall MedARD (interquartile range) was 12.7% (5.9-23.5) and MedARD differed significantly based on the rate of change in glucose (P < 0.001). An absolute difference of -22 mg/dL (-1.2 mmol/L) (95% limits of agreement [LoA] 60 mg/dL (3.3 mmol/L), -103 mg/dL (-5.7 mmol/L)) was found when glucose was rapidly increasing (isCGM glucose minus reference blood glucose), while a -32 mg/dL (1.8 mmol/L) (95% LoA 116 mg/dL (6.4 mmol/L), -51 mg/dL (-2.8 mmol/L)) absolute difference was observed in periods of rapidly decreasing glucose. Conclusions: The performance of isCGM was good when compared to reference blood glucose measurements. The rate of change in glucose for both increasing and decreasing glucose levels diminished isCGM performance, showing lower accuracy during high rates of glucose change. Keywords: continuous glucose monitoring (CGM); type 1 diabetes.
- Subjects :
- Adult
Blood Glucose
Periodisk scannet kontinuerlig glukosemåling
Adolescent
type 1 diabetes
Endocrinology, Diabetes and Metabolism
Intermittently scanned continuous glucose monitoring
Medical technology: 620 [VDP]
Endocrinology
Continuous glucose measurement
Diabetes Mellitus
Internal Medicine
Humans
Medisinsk teknologi: 620 [VDP]
Child
Glukosemåling
Kontinuerlig glukosemåling
Blood Glucose Self-Monitoring
continuous glucose monitoring (CGM)
Diabetes Mellitus, Type 1
Type 1 diabetes
Glucose
Glucose sensing
continuous glucose monitoring
typ 1 diabetes
Type 1
Subjects
Details
- ISSN :
- 14631326 and 14628902
- Volume :
- 24
- Database :
- OpenAIRE
- Journal :
- Diabetes, Obesity and Metabolism
- Accession number :
- edsair.doi.dedup.....f8dc9b3327e8e0490a2548e3c5eca65f