Back to Search
Start Over
Comparison of [11C]choline Positron Emission Tomography With T2- and Diffusion-Weighted Magnetic Resonance Imaging for Delineating Malignant Intraprostatic Lesions
- Source :
- International Journal of Radiation Oncology*Biology*Physics. 92:438-445
- Publication Year :
- 2015
- Publisher :
- Elsevier BV, 2015.
-
Abstract
- The purpose of this study was to compare the accuracy of [(11)C]choline positron emission tomography (CHOL-PET) with that of the combination of T2-weighted and diffusion-weighted (T2W/DW) magnetic resonance imaging (MRI) for delineating malignant intraprostatic lesions (IPLs) for guiding focal therapies and to investigate factors predicting the accuracy of CHOL-PET.This study included 21 patients who underwent CHOL-PET and T2W/DW MRI prior to radical prostatectomy. Two observers manually delineated IPL contours for each scan, and automatic IPL contours were generated on CHOL-PET based on varying proportions of the maximum standardized uptake value (SUV). IPLs identified on prostatectomy specimens defined reference standard contours. The imaging-based contours were compared with the reference standard contours using Dice similarity coefficient (DSC), and sensitivity and specificity values. Factors that could potentially predict the DSC of the best contouring method were analyzed using linear models.The best automatic contouring method, 60% of the maximum SUV (SUV60) , had similar correlations (DSC: 0.59) with the manual PET contours (DSC: 0.52, P=.127) and significantly better correlations than the manual MRI contours (DSC: 0.37, P.001). The sensitivity and specificity values were 72% and 71% for SUV60; 53% and 86% for PET manual contouring; and 28% and 92% for MRI manual contouring. The tumor volume and transition zone pattern could independently predict the accuracy of CHOL-PET.CHOL-PET is superior to the combination of T2W/DW MRI for delineating IPLs. The accuracy of CHOL-PET is insufficient for gland-sparing focal therapies but may be accurate enough for focal boost therapies. The transition zone pattern is a new classification that may predict how well CHOL-PET delineates IPLs.
- Subjects :
- Adult
Male
In vivo magnetic resonance spectroscopy
Cancer Research
medicine.medical_specialty
medicine.medical_treatment
Brachytherapy
Standardized uptake value
Multimodal Imaging
Sensitivity and Specificity
Choline
Fluorodeoxyglucose F18
Humans
Medicine
Radiology, Nuclear Medicine and imaging
Carbon Radioisotopes
Reference standards
Aged
Analysis of Variance
Contouring
Radiation
medicine.diagnostic_test
business.industry
Prostate
technology, industry, and agriculture
Prostatic Neoplasms
Magnetic resonance imaging
Middle Aged
Prostate-Specific Antigen
Reference Standards
Magnetic Resonance Imaging
Diffusion-Weighted Magnetic Resonance Imaging
Tumor Burden
Diffusion Magnetic Resonance Imaging
Oncology
Positron emission tomography
Positron-Emission Tomography
lipids (amino acids, peptides, and proteins)
Radiology
Radiopharmaceuticals
business
Nuclear medicine
Subjects
Details
- ISSN :
- 03603016
- Volume :
- 92
- Database :
- OpenAIRE
- Journal :
- International Journal of Radiation Oncology*Biology*Physics
- Accession number :
- edsair.doi.dedup.....f889f218c2aa442e8d1bbb95dd921028