Back to Search
Start Over
Diagnostic value of computed high b-value whole-body diffusion-weighted imaging for primary prostate cancer
- Source :
- European Journal of Radiology, 137:109581. ELSEVIER IRELAND LTD
- Publication Year :
- 2021
-
Abstract
- Purpose: To investigate the utility of post-acquisition computed diffusion-weighted imaging (cDWI) for primary prostate cancer (PCa) evaluation in biparametric whole-body MRI (bpWB-MRI).Methods: Patients who underwent pelvic MRI for PCa screening and subsequent bpWB-MRI for staging were included.Two radiologists assessed the diagnostic performance of the following datasets for clinically significant PCa diagnosis (grade group >= 2 according to the Prostate Imaging-Reporting and Data System, version 2.1): bpMRI(2000) (axial DWI scans with a b-value of 2,000 s/mm(2) + axial T2WI scans from pre-biopsy pelvic MRI), computed bpWB-MRI2000 (computed WB-DWI scans with a b-value of 2,000 s/mm(2) + axial WB-T2WI scans), and native bpWB-MRI1000 (native axial WB-DWI scans with a b-value of 1,000 s/mm(2) + axial WB-T2WI scans). Systemic biopsy was used as reference standard.Results: Fifty-one patients with PCa were included. The areas under the curve (AUCs) of bpMRI(2000) (0.89 for reader 1 and 0.86 for reader 2) and computed bpWB-MRI2000 (0.86 for reader 1 and 0.83 for reader 2) were significantly higher (p < 0.001) than those of native bpWB-MRI1000 (0.67 for both readers). No significant difference was observed between the AUCs of bpMRI(2000) and computed bpWB-MRI2000 (p = 0.10 for reader 1 and p = 0.25 for reader 2).Conclusions: The diagnostic performance of computed bpWB-MRI2000 was similar to that of dedicated pelvic bpMRI(2000) for primary PCa evaluation. cDWI can be recommended for implementation in standard WB-MRI protocols to facilitate a one-step evaluation for concurrent detection of primary and metastatic PCa.
- Subjects :
- Male
Diffusion-weighted magnetic resonance imaging
Biopsy
Whole body imaging
030218 nuclear medicine & medical imaging
03 medical and health sciences
Prostate cancer
0302 clinical medicine
Magnetic resonance imaging
Prostate
medicine
Humans
Radiology, Nuclear Medicine and imaging
Whole-body imaging
medicine.diagnostic_test
business.industry
Prostatic Neoplasms
General Medicine
High B-Value
medicine.disease
Diffusion Magnetic Resonance Imaging
medicine.anatomical_structure
030220 oncology & carcinogenesis
business
Whole body
Nuclear medicine
Diffusion MRI
Subjects
Details
- Language :
- English
- ISSN :
- 0720048X
- Volume :
- 137
- Database :
- OpenAIRE
- Journal :
- European Journal of Radiology
- Accession number :
- edsair.doi.dedup.....f85ae374deacb33c9fe16eb715b66dce