Back to Search
Start Over
Computed Tomography Images under Optimized Iterative Reconstruction Algorithm for Blood Flow Field Characteristics in Cerebral Aneurysm before and after Stent Implantation
- Source :
- Scientific Programming, Vol 2021 (2021)
- Publication Year :
- 2021
- Publisher :
- Hindawi Limited, 2021.
-
Abstract
- In order to study the analysis of blood flow field characteristics of cerebral aneurysm patients before and after stent implantation based on CT images of ART-TV-PI, this paper firstly improved the ART-TV algorithm of algebraic reconstruction technology and obtained the ART-TV-PI algorithm, which was compared with the ART algorithm and ART-TV algorithm. Afterwards, the CT images based on the above three algorithms were used to analyze the changes of average blood flow velocity, average wall pressure, average wall deformation, and average shear force of 48 cases of cerebral aneurysm patients before and after stent implantation. The results showed that the mean square error and radiation dose of the ART-TV-PI algorithm (0.00012 and 1.65 mSv) were significantly lower than those of the ART algorithm (0.0031 and 3.09 mSv) and ART-TV algorithm (0.00082 and 2.52 mSv), and the signal-to-noise ratio (23.94) was significantly higher than those of the ART algorithm (11.32) and ART-TV algorithm (16.89), with statistically significant differences ( P < 0.05 ). The differences of mean blood flow velocity, mean wall pressure, mean wall deformation, and mean shear force before and after stent implantation among the three algorithms were not statistically significant ( P > 0.05 ), and the average index of the ART-TV-PI algorithm was the highest. Under the ART-TV-PI algorithm, the mean blood flow velocity (0.044 m/s), the mean wall pressure (71.7 Pa), the mean wall deformation (0.057 mm), and the mean shear force (889 Pa) after stent implantation were significantly lower than those before stent implantation (0.165 m/s, 160.8 Pa, 0.721 mm, and 2690 Pa), with average decreases of 73.3%, 55.4%, 92.1%, and 64.3%, respectively, and the differences were statistically significant ( P < 0.05 ). In conclusion, the images reconstructed by the ART-TV-PI algorithm have good image quality, which provides great convenience for surgical examination of cerebral aneurysm stent implantation and is worthy of clinical application.
- Subjects :
- Article Subject
Mean squared error
medicine.diagnostic_test
Shear force
Computed tomography
Blood flow
Iterative reconstruction
medicine.disease
030218 nuclear medicine & medical imaging
Computer Science Applications
QA76.75-76.765
03 medical and health sciences
0302 clinical medicine
Aneurysm
medicine
Stent implantation
Computer software
Mean Blood Flow Velocity
Algorithm
030217 neurology & neurosurgery
Software
Mathematics
Subjects
Details
- ISSN :
- 1875919X and 10589244
- Volume :
- 2021
- Database :
- OpenAIRE
- Journal :
- Scientific Programming
- Accession number :
- edsair.doi.dedup.....f840010ad8b8abb4810c43620808e15e
- Full Text :
- https://doi.org/10.1155/2021/8982101