Back to Search
Start Over
Comparison of pulmonary artery dimensions in swine obtained from catheter angiography, multi-slice computed tomography, 3D-rotational angiography and phase-contrast magnetic resonance angiography
- Source :
- The International Journal of Cardiovascular Imaging
- Publication Year :
- 2020
- Publisher :
- Springer Science and Business Media LLC, 2020.
-
Abstract
- Accurate pulmonary artery (PA) imaging is necessary for management of patients with complex congenital heart disease (CHD). The ability of newer imaging modalities such as 3D rotational angiography (3DRA) or phase-contrast magnetic resonance angiography (PC-MRA) to measure PA diameters has not been compared to established angiography techniques. Measurements of PA diameters (including PA stenosis and PA stents) from 3DRA and non-contrast-enhanced PC-MRA were compared to 2D catheter angiography (CA) and multi-slice computed tomography (MSCT) in a swine CHD model (n = 18). For all PA segments 3DRA had excellent agreement with CA and MSCT (ICC = 0.94[0.91–0.95] and 0.92[0.89–0.94]). 3DRA PA stenosis measures were similar to CA and MSCT and 3DRA was on average within 5% of 10.8 ± 1.3 mm PA stent diameters from CA and MSCT. For compliant PA segments, 3DRA was on average 3–12% less than CA (p
- Subjects :
- Pulmonary artery imaging
Heart Defects, Congenital
Male
Computed Tomography Angiography
medicine.medical_treatment
Sus scrofa
Pulmonary artery stenosis
Pulmonary Artery
030204 cardiovascular system & hematology
Magnetic resonance angiography
030218 nuclear medicine & medical imaging
03 medical and health sciences
Imaging, Three-Dimensional
0302 clinical medicine
Predictive Value of Tests
medicine.artery
Multidetector Computed Tomography
medicine
Animals
Stenosis, Pulmonary Artery
Radiology, Nuclear Medicine and imaging
Cardiac imaging
Congenital heart disease
Original Paper
medicine.diagnostic_test
business.industry
Endovascular Procedures
Reproducibility of Results
Stent
medicine.disease
Disease Models, Animal
Stenosis
Catheter angiography
3d rotational angiography
Catheterization, Swan-Ganz
Pulmonary artery
Stents
Cardiology and Cardiovascular Medicine
Nuclear medicine
business
Magnetic Resonance Angiography
Subjects
Details
- ISSN :
- 15730743 and 15695794
- Volume :
- 37
- Database :
- OpenAIRE
- Journal :
- The International Journal of Cardiovascular Imaging
- Accession number :
- edsair.doi.dedup.....f7fc3264101e3315ba8b4adf3f04e1b7
- Full Text :
- https://doi.org/10.1007/s10554-020-02043-9