AC flashover performance of different shed configurations of composite insulators under fan-shaped non-uniform pollution
- Source :
- High Voltage (2018)
- Publication Year :
- 2018
- Publisher :
- Wiley, 2018.
-
Abstract
- Currently, it is founded that under unidirectional wind and certain landform, composite insulators are always fan-shaped non-uniformly polluted. In this paper, artificial pollution tests on three types of composite insulators with different shed configurations and under various fan-shaped non-uniform pollution conditions were carried out. Then the flashover performances of composite insulators, porcelain insulators and glass insulators were compared. Results indicate that there is a big difference between ac flashover performance of composite insulators under non-uninform pollution and uninform pollution. The flashover voltage of composite insulator is largely influenced by salt deposit density (SDD), the ratio of SDD of windward side to leeward side (W/L), the occupation ratio of leeward side k and the shed configurations. The relationship between SDD and U 50 still meets negative power function when composite insulator is fan-shaped non-uninform polluted. There is a reduction of 17.8–27.6% in the flashover strength when the ratio W/L of SDD decreases from 1/1 to 1/15. The shed configurations of composite insulators have great effects on the flashover performance. Composite insulators always have better withstand property compared to glass and porcelain insulators under either uniform pollution or fan-shaped non-uniform pollution.
- Subjects :
- Pollution
composite insulator
Materials science
020209 energy
media_common.quotation_subject
flashover
glass insulators
lcsh:QC501-721
Energy Engineering and Power Technology
02 engineering and technology
Composite insulators
01 natural sciences
Flashover voltage
shed configurations
0103 physical sciences
lcsh:Electricity
0202 electrical engineering, electronic engineering, information engineering
Arc flash
power transmission
salt deposit density
Electrical and Electronic Engineering
Composite material
Salt deposit density
artificial pollution tests
media_common
010302 applied physics
transmission lines
creepage distance utilisation rate
composite insulators
wind power
Electric power transmission
porcelain insulators
unidirectional wind landform
flashover voltage
Negative power
lcsh:Electrical engineering. Electronics. Nuclear engineering
lcsh:TK1-9971
insulator testing
AC flashover performance
fan-shaped nonuniform pollution
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- High Voltage (2018)
- Accession number :