Back to Search
Start Over
Intra-fraction and Inter-fraction analysis of a dedicated immobilization device for intracranial radiation treatment
- Source :
- Radiation Oncology (London, England), Radiation Oncology, Vol 15, Iss 1, Pp 1-7 (2020)
- Publication Year :
- 2020
- Publisher :
- Springer Science and Business Media LLC, 2020.
-
Abstract
- Background Immobilization devices are crucial to minimize patient positioning uncertainties in radiotherapy (RT) treatments. Accurate inter and intra-fraction motions is particularly important for intracranial and stereotactic radiation treatment which require high precision in dose delivery. Recently, a new immobilization device has been developed specifically for the radiation treatment of intracranial malignancies. To date, no data are available on the use of this device in daily clinical practice. The aim of this study is to investigate the intra and inter-fraction variations, patient comfort and radiographer confidence of the immobilization system from two distinct institutions: HagaZiekenhuis, Den Haag, Netherlands and IRCCS Ospedale Sacro Cuore Don Calabria, Negrar, Italy. Material and method Sixteen patients (10 diagnosed with brain metastases and 6 with primary central nervous systemic tumor) from IRCCS Ospedale Sacro Cuore Don Calabria and 17 patients (all diagnosed with brain metastases tumor) from HagaZiekenhuis were included in this study. The median target volume was 436 cc (range 3.2–1628 cc) and 4.58 cc (range 0.4–27.19 cc) for IRCCS and Haga, respectively. For patients treated in IRCCS Sacro Cuore Don Calabria, the median dose prescription was 30 Gy (range 27–60 Gy) and median number of fractions 10 (range 3–30). In Haga the median dose prescription was 21 Gy (range 8–21 Gy) and the median number of fraction was 1 (range 1–3). The immobilization device was assembled during CT simulation. A short interview to the patient regarding the device’s comfort level was conducted at the end of the simulation procedure. Additionally, simulation setup time and radiographer (RTT) procedures (i.e. mask preparation) were evaluated. Prior to radiation treatment delivery, an automatic rigid match on the cranial bones between cone beam computed tomography (CBCT) and planning-CT was performed. A couch shift was performed subsequently. An extra post-treatment CBCT was acquire after the treatment delivery. This post-treatment CBCT was matched with pre-treatment CBCT to identify any possible intra-fraction motion. All online matches were validated by experienced radiation oncologist or RTT. A total of 126 CBCT’s were analyzed offline by radiation oncologist/medical physicist. The data of the pre-treatment CBCT match was used to quantify inter-fraction motion. The post-treatment CBCT was matched with pre-treatment CBCT to identify any possible intra-fraction motion. Results During the molding of the mask, all patients responded positive to the comfort. Median time required by the RTTs to assemble the immobilization system was 9 min (range 6–12 min). In terms of comfort, all patients reported a good-to high level of satisfaction. The RTTs also respond positively towards the use of the locking mechanism and clips. Results of positioning uncertainties were comparable between the two institutes. The mean inter-fraction motion for all translational and rotational directions were Conclusions This study demonstrates the efficacy and feasibility of the immobilization device in the intracranial radiation treatment. Both patient comfort and preparation time by RTTs are considered adequate. In combination with online daily imaging procedure, this device can achieve submillimeter accuracy required for intracranial and stereotactic treatments.
- Subjects :
- Male
Cone beam computed tomography
medicine.medical_treatment
Central Nervous System Neoplasms
0302 clinical medicine
Image Processing, Computer-Assisted
Radiation oncologist
Netherlands
Aged, 80 and over
Brain Neoplasms
Brain
Radiotherapy Dosage
Cone-Beam Computed Tomography
Middle Aged
lcsh:Neoplasms. Tumors. Oncology. Including cancer and carcinogens
Prognosis
Italy
Oncology
Treatment delivery
030220 oncology & carcinogenesis
Female
lcsh:Medical physics. Medical radiology. Nuclear medicine
Adult
Adolescent
lcsh:R895-920
Movement
Intra-fraction
lcsh:RC254-282
Patient Positioning
Medical physicist
Immobilization
Young Adult
03 medical and health sciences
medicine
Humans
Radiology, Nuclear Medicine and imaging
Fraction (mathematics)
Aged
Dose delivery
Radiotherapy
business.industry
Research
Radiotherapy Planning, Computer-Assisted
Inter-fraction
Dose prescription
Radiation therapy
Radiotherapy, Intensity-Modulated
Nuclear medicine
business
Radiotherapy, Image-Guided
Subjects
Details
- ISSN :
- 1748717X
- Volume :
- 15
- Database :
- OpenAIRE
- Journal :
- Radiation Oncology
- Accession number :