Back to Search
Start Over
Clinical evaluation of the air-handling properties of contemporary oxygenators with integrated arterial filter
- Source :
- Perfusion, 32(2), 118-125. SAGE Publications Ltd
- Publication Year :
- 2017
-
Abstract
- Gaseous microemboli (GME) may originate from the extracorporeal circuit and enter the arterial circulation of the patient. GME are thought to contribute to cerebral deficit and to adverse outcome after cardiac surgery. The arterial filter is a specially designed component for removing both gaseous and solid microemboli. Integration of an arterial filter with an oxygenator is a contemporary concept, reducing both prime volume and foreign surface area. This study aims to determine the air-handling properties of four contemporary oxygenator devices with an integrated arterial filter. Two oxygenator devices, the Capiox FX25 and the Fusion, showed significant increased volume of GME reduction rates (95.03 ± 3.13% and 95.74 ± 2.69%, respectively) compared with both the Quadrox-IF (85.23 ± 5.84%) and the Inspire 6F M (84.41 ± 12.93%). Notably, both the Quadrox-IF and the Inspire 6F M as well as the Capiox FX 25 and the Fusion showed very similar characteristics in volume and number reduction rates and in detailed distribution properties. The Capiox FX25 and the Fusion devices showed significantly increased number and volume reduction rates compared with the Quadrox-IF and the Inspire 6F M devices. Despite the large differences in design of all four devices, our study results suggest that the oxygenator devices can be subdivided into two groups based on their fibre design, which results in screen filter (Quadrox-IF and Inspire 6F M) and depth filter (Capiox FX25 and Fusion) properties. Depth filter properties, as present in the Capiox FX25 and Fusion devices, reduced fractionation of air and may ameliorate GME removal.
- Subjects :
- Male
medicine.medical_specialty
Oxygenators
Adverse outcomes
030204 cardiovascular system & hematology
Embolic Protection Devices
law.invention
Screen filter
03 medical and health sciences
0302 clinical medicine
law
medicine
Cardiopulmonary bypass
Embolism, Air
Humans
Radiology, Nuclear Medicine and imaging
Prospective Studies
Oxygenator
Aged
Aged, 80 and over
Advanced and Specialized Nursing
Cardiopulmonary Bypass
business.industry
Arteries
General Medicine
Middle Aged
Surgery
030228 respiratory system
Filter (video)
Depth filter
Female
Cardiology and Cardiovascular Medicine
business
Safety Research
Clinical evaluation
Biomedical engineering
Subjects
Details
- Language :
- English
- ISSN :
- 02676591
- Volume :
- 32
- Issue :
- 2
- Database :
- OpenAIRE
- Journal :
- Perfusion
- Accession number :
- edsair.doi.dedup.....f7212401a877e2d9157a272b3af791f6
- Full Text :
- https://doi.org/10.1177/0267659116664402