Pediatric cone beam CT on Varian Halcyon and TrueBeam radiotherapy systems: radiation dose and positioning accuracy evaluations
- Source :
- Journal of Radiological Protection. 39:739-748
- Publication Year :
- 2019
- Publisher :
- IOP Publishing, 2019.
-
Abstract
- Medical exposure to ionizing irradiation has become a recognised carcinogenic risk. Balancing the concomitant imaging dose and positioning accuracy is critical in image-guided-radiotherapy (IGRT) especially for children, whose higher biological susceptibility and longer expected life make them more vulnerable to develop secondary cancer. This work aims to evaluate and benchmark the imaging dose and positioning accuracy of a new MV cone-beam-CT (CBCT)-guided IGRT system, Varian Halcyon, against conventional kV CBCT. Weighted-CT-dose-index (CTDIw) were measured for Varian TrueBeam kV CBCT, and computed for Halcyon MV CBCT using Eclipse system as validated before. Simulating the IGRT workflow, the positioning accuracy of correcting a known shift was tested on various regions of 1-year, 5-year and adult anthropomorphic phantoms, respectively. Inter-scanner and inter-protocol comparisons of dose and accuracy were performed. kV CTDIw for 'Head', 'Thorax', 'Pelvis' and 'Image Gently' (in CTDIΦ16cm/CTDIΦ32cm phantoms, respectively) protocols were measured as 4.5 mGy, 5.4 mGy, 19.3 mGy, and 1.1 mGy/0.5 mGy, respectively. Using 'High Quality' mode, MV CTDIw in the CTDIΦ16cm and CTDI Φ32cm phantoms were computed as 84.5 mGy and 63.8 mGy (imaging length = 28 cm), 68.8 mGy and 55.5 mGy (imaging length = 16 cm), respectively, which were about twice of 'Low Dose' mode. The maximum positioning deviation observed on Halcyon was 0.51 mm ('Low Dose' adult thorax), which was lower than that of standard (0.58 mm, 'Pelvis' adult pelvis) and 'Image Gently' kV CBCT (1.57 mm, adult pelvis). Accuracy of 'Image Gently' kV CBCT head & neck and thoracic imaging were clinically acceptable for adults (maximum deviation = 0.54 mm, adult thorax). Complying with Image Gently campaign, dose-efficient protocols should be used for pediatric IGRT, achieving comparable positioning accuracy on the new Halcyon MV CBCT system relative to the conventional kV CBCT.
- Subjects :
- Quality Control
Secondary cancer
medicine.medical_treatment
Maximum deviation
Patient Positioning
030218 nuclear medicine & medical imaging
03 medical and health sciences
Radiation Protection
0302 clinical medicine
Humans
Medicine
Child
Waste Management and Disposal
Cone beam ct
Image-guided radiation therapy
Phantoms, Imaging
business.industry
Radiation dose
Public Health, Environmental and Occupational Health
Truebeam
Radiotherapy Dosage
General Medicine
Cone-Beam Computed Tomography
Radiation therapy
030220 oncology & carcinogenesis
Tomography
business
Nuclear medicine
Radiotherapy, Image-Guided
Subjects
Details
- ISSN :
- 13616498 and 09524746
- Volume :
- 39
- Database :
- OpenAIRE
- Journal :
- Journal of Radiological Protection
- Accession number :
- edsair.doi.dedup.....f478da97c624e061e6f16a2d9fc2f287
- Full Text :
- https://doi.org/10.1088/1361-6498/ab1e74