Back to Search
Start Over
Methodologic Issues in the Measurement of Urinary Renin
- Source :
- Clinical Journal of the American Society of Nephrology, 9(7), 1163-1167. American Society of Nephrology
- Publication Year :
- 2014
-
Abstract
- Background and objectives Alge et al. recently reported that urinary renin may be a prognostic biomarker for AKI after cardiac surgery. However, their urinary renin levels far exceeded published plasma renin levels, whereas normally, urinary renin is,10% of plasma renin. This result raises questions about the specificity of the new Quantikine Renin ELISA Kit used in the work by Alge et al., which is claimed to detect total renin (i.e., renin and prorenin). Therefore, this study tested this assay. Design, setting, participants, & measurements Plasma and urine from 30 patients with hypertension, diabetes, or preeclampsia and 10 healthy pregnant women (randomly selected from sample sets obtained earlier to investigate urinary renin-angiotensin system components) were used to compare the ELISA with a validated renin immunoradiometricassay and an in-house enzyme kinetic assay. Measurements were performed before and after in vitro prorenin activation, representing renin and total renin, respectively. Results Total renin measurements by ELISA, immunoradiometric assay, and enzyme kinetic assay were highly correlated. However, ELISA results were consistently $10-fold higher. The ELISA standard yielded low to undetectable levels in the immunoradiometric assay and enzyme kinetic assay, except after prorenin activation, when the results were $10-fold lower than the ELISA results. In plasma, prorenin activation increased ELISA results by 10%–15%. Urine contained no detectable prorenin. Conclusions The ELISA renin kit standard is prorenin, and its immunoreactivity and enzymatic activity after conversion to renin do not match the International Reference Preparation of human renin that has been used to validate previous immunoradiometric assays and enzyme kinetic assays; in fact, they are at least 10-fold lower, and thus, any measurements obtained with this ELISA kit yield levels that are at least 10-fold too high. The ELISA antibodies detect both renin and prorenin, with a preference for the former. Given these inconsistencies, urinary renin levels should be measured by established renin assays. Clin J Am Soc Nephrol 9: ccc–ccc, 2014. doi: 10.2215/CJN.12661213
- Subjects :
- Adult
Male
medicine.medical_specialty
Epidemiology
Urinary system
Enzyme-Linked Immunosorbent Assay
Urine
Critical Care and Intensive Care Medicine
Plasma renin activity
Preeclampsia
SDG 3 - Good Health and Well-being
Predictive Value of Tests
Pregnancy
Internal medicine
Renin
Renin–angiotensin system
medicine
Humans
Diabetic Nephropathies
Aged
Enzyme Precursors
Transplantation
Immunoradiometric assay
biology
business.industry
Reproducibility of Results
Original Articles
Middle Aged
Reference Standards
medicine.disease
Endocrinology
Nephrology
Case-Control Studies
Calibration
biology.protein
Albuminuria
Female
Immunoradiometric Assay
Kidney Diseases
Reagent Kits, Diagnostic
Antibody
medicine.symptom
business
Biomarkers
Subjects
Details
- ISSN :
- 15559041
- Volume :
- 9
- Issue :
- 7
- Database :
- OpenAIRE
- Journal :
- Clinical Journal of the American Society of Nephrology
- Accession number :