Evaluation of a Novel Noninvasive Blood Glucose Monitor Based on Mid-Infrared Quantum Cascade Laser Technology and Photothermal Detection
- Source :
- Journal of Diabetes Science and Technology
- Publication Year :
- 2020
- Publisher :
- SAGE Publications, 2020.
-
Abstract
- Background: A prototype of a noninvasive glucometer combining skin excitation by a mid-infrared quantum cascade laser with photothermal detection was evaluated in glucose correlation tests including 100 volunteers (41 people with diabetes and 59 healthy people). Methods: Invasive reference measurements using a clinical glucometer and noninvasive measurements at a finger of the volunteer were simultaneously recorded in five-minute intervals starting from fasting glucose values for healthy subjects (low glucose values for diabetes patients) over a two-hour period. A glucose range from >50 to Results: 98.8% (full data set) and 99.1% (improved algorithm) of glucose results were within Zones A and B of the grid, indicating the highest accuracy level. Less than 1% of the data were in Zone C, and none in Zone D or E. The mean and median percent differences between the invasive as a reference and the noninvasive method were 12.1% and 6.5%, respectively, for the full data set, and 11.3% and 6.4% with the improved algorithm. Conclusions: Our results demonstrate that noninvasive blood glucose analysis combining mid-infrared spectroscopy and photothermal detection is feasible and comparable in accuracy with minimally invasive glucometers and finger pricking devices which use test strips. As a next step, a handheld version of the present device for diabetes patients is being developed.
- Subjects :
- Blood Glucose
Technology
Materials science
photothermal detection
Endocrinology, Diabetes and Metabolism
Biomedical Engineering
Mid infrared
Bioengineering
02 engineering and technology
01 natural sciences
law.invention
law
Internal Medicine
Humans
Special Section: Non-Invasive Glucose Monitoring
Thesaurus (information retrieval)
business.industry
Blood Glucose Self-Monitoring
010401 analytical chemistry
Guest Editors: Michael Heise, Mark Arnold, and Ishan Barman
Photothermal therapy
noninvasive blood glucose analysis
021001 nanoscience & nanotechnology
0104 chemical sciences
Glucose
Optoelectronics
Lasers, Semiconductor
quantum cascade laser (QCL)
0210 nano-technology
business
Quantum cascade laser
mid-IR spectroscopy
Subjects
Details
- ISSN :
- 19322968
- Volume :
- 15
- Database :
- OpenAIRE
- Journal :
- Journal of Diabetes Science and Technology
- Accession number :
- edsair.doi.dedup.....f3c15a372fa3c2c62d17d6311ac46552
- Full Text :
- https://doi.org/10.1177/1932296820936634