Back to Search Start Over

Acute diastolic dysfunction in thoracoabdominal aortic aneurysm surgery

Authors :
Claudio S. Cinà
Howard J. Nathan
Homer Yang
Ashraf Fayad
Gregory L. Bryson
Source :
Canadian Journal of Anesthesia/Journal canadien d'anesthésie. 53:168-173
Publication Year :
2006
Publisher :
Springer Science and Business Media LLC, 2006.

Abstract

Purpose: To report transesophageal echocardiographic (TEE) findings consistent with intraoperative acute diastolic dysfunction in a series of patients undergoing thoracoabdominal aortic aneurysm (TAAA) repair. Methods: A series of nine consecutive patients underwent TAAA repair with intraoperative TEE monitoring. Surgical repair was performed with the adjunct of a left atrio-femoral bypass. Invasive arterial and venous pressures were monitored. Intraoperative TEE was utilized to assess the diastolic function before, and during aortic cross clamping. Diastolic dysfunction was defined as a mitral inflow pulsed wave Doppler (E: A ratio) 1 (1.3 ± 0.08) before aortic cross clamping. During cross clamp, the E: A ratio decreased to 1 (1.2 ± 0.09). Three of the patients with intraoperative diastolic dysfunction developed postoperative myocardial infarction. Conclusions: Chronic diastolic dysfunction is a well-known entity. This report describes acute diastolic dysfunction, which was observed frequently in patients undergoing TAAA during aortic cross clamp. Further research is required to confirm this phenomenon and determine its possible association with increased postoperative cardiac morbidity. Objectif : Presenter les resultats de l’echocardiographie transœsophagienne (ETO) compatibles avec une dysfonction peroperatoire diastolique aigue chez une serie de patients operes pour un anevrysme aortique thoraco-abdominal (AATA). Methode : Neuf patients consecutifs ont subi la reparation d’un AATA sous monitorage peroperatoire avec ETO. Une derivation auriculo-femorale gauche et un monitorage endovasculaire des pressions arterielle et veineuse ont ete utilises. L’ETO peroperatoire a servi a evaluer la fonction diastolique avant et pendant le clampage de la crosse aortique. La dysfonction diastolique etait une onde Doppler pulsee d’entree mitrale (ratio E : A) < 1.

Details

ISSN :
14968975 and 0832610X
Volume :
53
Database :
OpenAIRE
Journal :
Canadian Journal of Anesthesia/Journal canadien d'anesthésie
Accession number :
edsair.doi.dedup.....f2bdfbfc0ad70da3b9ac787b9d354617
Full Text :
https://doi.org/10.1007/bf03021823