Back to Search
Start Over
Comparison of different methods used in drugs of abuse for sample validity testing including pH methods, specific gravity methods, TECO™ Drug Adulteration Test Strip and oxidant assay
- Source :
- Advances in Laboratory Medicine, Vol 2, Iss 4, Pp 550-557 (2021)
- Publication Year :
- 2021
- Publisher :
- De Gruyter, 2021.
-
Abstract
- Objectives In the absence of sample validity testing, a healthcare provider may fail to identify a patient’s adulteration of their urine sample. This study compared different methods for specific gravity (SG), pH, TECO™ Drug Adulteration Test Strip (dipstick) and oxidant assay to explain the differences and also make an informative decision on method selection. Methods Creatinine, SG and pH measurements are essential in sample validity testing. SG and pH automated chemical methods are compared against pH meter method, SG refractometer and dipstick method. Also, oxidant assay was compared against dipstick method. Results SG chemical method agreement with refractometer is 81.9% and with dipstick method is 64.7%. The refractometer method agreement with dipstick method is 66.1%. pH chemical method agreement with pH Meter method is 74.3% and with dipstick method is 81.4%. pH meter method agreement is 85.7% with dipstick method. Results were analysed using Deming regression analysis and F-test. SG chemical method correlated better with refractometer than the dipstick method. Oxidant assay correlated well with dipstick method in detecting adulterants such as pyridinium chlorochromate, nitrite and bleach. Conclusions Varying degrees of differences were seen in the SG and pH measurements. These differences were both method and instrument dependent. The automated chemical methods are recommended alongside oxidant assay for consistency, accuracy and faster turn-around time as part of sample validity testing for drugs of abuse.
- Subjects :
- 021110 strategic, defence & security studies
Drugs of abuse
Chromatography
040301 veterinary sciences
business.industry
ph
Sample (material)
0211 other engineering and technologies
sample validity
Medicine (miscellaneous)
oxidant assay
Drug Adulteration
04 agricultural and veterinary sciences
02 engineering and technology
drug adulteration
Education
Test (assessment)
0403 veterinary science
Medical Laboratory Technology
Medical technology
Medicine
R855-855.5
business
specific gravity
Specific gravity
Subjects
Details
- Language :
- English
- Volume :
- 2
- Issue :
- 4
- Database :
- OpenAIRE
- Journal :
- Advances in Laboratory Medicine
- Accession number :
- edsair.doi.dedup.....f20447f1f822a475df4fab40e267bd54