Luminal diameter and vasa vasorum response to stent dilation in the rabbit aorta
- Source :
- Academic radiology. 3(7)
- Publication Year :
- 1996
-
Abstract
- We examined the changes in luminal diameter and vasa vasorum after stent dilation of the aorta of nonatherosclerotic rabbits.Balloon-expandable stents were placed in the aortas of rabbits at the L3 level and were expanded. After 8 weeks, the rabbits were euthanized, perfused with barium sulfate particles, frozen, sectioned, and X-rayed.The luminal intrastent diameter (2.3 +/- 0.23 mm) was significantly different (p.05) from the expanded stent diameter but was not different from the luminal diameter above (2.3 +/- 0.53 mm) and below (1.9 +/- 0.18 mm) the stent. The number of vasa vasorum at the stent (46 +/- 7.2) was significantly increased compared with above (21 +/- 4.8, p.001) and below (14.4 +/- 4.6, p.001) the stent.After 8 weeks, luminal diameter was uniform. The increased vasa vasorum in the stented section suggested an increase in blood flow to the aortic wall, which may be important to the remodeling process.
- Subjects :
- medicine.medical_treatment
Aortography
chemistry.chemical_compound
medicine.artery
medicine
Animals
Radiology, Nuclear Medicine and imaging
Aorta, Abdominal
Aorta
Luminal diameter
business.industry
Vasa Vasorum
Rabbit aorta
Stent
Blood flow
Anatomy
Adaptation, Physiological
Dilatation
Barium sulfate
medicine.anatomical_structure
chemistry
Vasa vasorum
cardiovascular system
Dilation (morphology)
Stents
Rabbits
business
Subjects
Details
- ISSN :
- 10766332
- Volume :
- 3
- Issue :
- 7
- Database :
- OpenAIRE
- Journal :
- Academic radiology
- Accession number :
- edsair.doi.dedup.....f03b2bdb0e0d447b83aeb478806809b8