Back to Search Start Over

Mobile tablets for real-time data collection for hospital-based birth defects surveillance in Kampala, Uganda: Lessons learned

Authors :
Dennis Kalibbala
Ayoub Kakande
Robert Serunjogi
Dhelia Williamson
Daniel Mumpe-Mwanja
Joyce Namale-Matovu
Diana Valencia
Beatrice Nalwoga
Christine Namirembe
Joan Seyionga
Margaret Nanfuka
Sophia Nakimuli
Margaret Okwero Achom
Kenneth Mwambi
Philippa Musoke
Linda Barlow-Mosha
Source :
PLOS global public health. 2(6)
Publication Year :
2023

Abstract

Sustainable birth defects surveillance systems provide countries with estimates of the prevalence of birth defects to guide prevention, care activities, and evaluate interventions. We used free and open-source software (Open Data Kit) to implement an electronic system to collect data for a hospital-based birth defects surveillance system at four major hospitals in Kampala, Uganda. We describe the establishment, successes, challenges, and lessons learned from using mobile tablets to capture data and photographs. After intensive training, surveillance midwives collected data using Android tablets with inbuilt logic checks; another surveillance midwife checked the quality of the data in real-time before data were securely uploaded onto a local server. Paper forms were used when needed as a backup for the electronic system. We experienced several challenges implementing the surveillance system, including forgotten passwords, unstable network, reduced tablet speed and freezing, loss of touch-screen sensitivity, decreased battery strength, and repetitive extensive retraining. We addressed these challenges by backing up and removing all photos from the tablet, uninstalling irrelevant applications to the study to increase storage space and speed, and monitoring and updating the system based mainly on feedback from the midwives. From August 2015 to December 2018, surveillance midwives documented information on 110,752 births at the participating hospitals. Of these, 110,573 (99.8%) were directly entered into the electronic data system and 179 (0.2%) were captured on paper forms. The use of mobile tablets for real-time data collection was successful in a hospital-based birth defects surveillance system in a resource-limited setting. Extensive training and follow-up can overcome challenges and are key to preparing staff for a successful data collection system.

Details

ISSN :
27673375
Volume :
2
Issue :
6
Database :
OpenAIRE
Journal :
PLOS global public health
Accession number :
edsair.doi.dedup.....eed53d7425461046f7e22522d390c9fd