Back to Search Start Over

Low-dose dual-isotope procedure planed for myocardial perfusion CZT-SPECT and assessed through a head-to-head comparison with a conventional single-isotope protocol

Authors :
Gilles Karcher
Charles Merlin
Véronique Roch
Laetitia Imbert
Florent Cachin
Pierre-Yves Marie
Wassila Djaballah
Antoine Verger
Marine Claudin
Mathieu Perrin
Henri Boutley
Service de Médecine Nucléaire [Nancy]
Centre Hospitalier Régional Universitaire de Nancy (CHRU Nancy)
Nancyclotep- Experimental Imaging Platform = Plate-forme d'imagerie moléculaire
Centre Hospitalier Régional Universitaire de Nancy (CHRU Nancy)-Université de Lorraine (UL)
Imagerie Adaptative Diagnostique et Interventionnelle (IADI)
Université de Lorraine (UL)-Institut National de la Santé et de la Recherche Médicale (INSERM)
Institut de Cancérologie de Lorraine - Alexis Vautrin [Nancy] (UNICANCER/ICL)
UNICANCER
Centre Jean Perrin [Clermont-Ferrand] (UNICANCER/CJP)
Imagerie Moléculaire et Thérapie Vectorisée (IMTV)
Université d'Auvergne - Clermont-Ferrand I (UdA)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Cancéropôle CLARA-ITMO ' Technologies pour la Santé '
Université de Lorraine (UL)
Faculté de Médecine [Nancy]
Défaillance Cardiovasculaire Aiguë et Chronique (DCAC)
Centre Hospitalier Régional Universitaire de Nancy (CHRU Nancy)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Université de Lorraine (UL)
Institut National de la Santé et de la Recherche Médicale (INSERM)-Université de Lorraine (UL)
ITMO ' Technologies pour la Santé '-Cancéropôle CLARA-Institut National de la Santé et de la Recherche Médicale (INSERM)-Université d'Auvergne - Clermont-Ferrand I (UdA)
Service de Médecine Nucléaire [CHRU Nancy]
Source :
Journal of Nuclear Cardiology, Journal of Nuclear Cardiology, Springer Verlag, 2017, 25 (6), pp.2016-2023. ⟨10.1007/s12350-017-0914-z⟩, Journal of Nuclear Cardiology, 2017, 25 (6), pp.2016-2023. ⟨10.1007/s12350-017-0914-z⟩
Publication Year :
2017
Publisher :
Springer Science and Business Media LLC, 2017.

Abstract

International audience; Purpose of the report: This study aimed at assessing an original low-dose dual-isotope procedure in which the abnormal stress Tc-99m Sestamibi SPECT is followed by rest Tl-201 SPECT, along with a head-to-head comparison with a single-isotope procedure.Methods and results: One hundred two patients, referred for a low-dose stress-SPECT with Sestamibi (123 ± 20 MBq) on a CZT camera and for whom a rest Sestamibi SPECT was warranted, had an additional Tl-201 rest-SPECT (52 ± 5 MBq) between stress and rest Sestamibi SPECT recordings. Tl-201 images were processed for spill-over and scatter corrections, and uptake differences with stress Sestamibi SPECT were analyzed: (1) for rest acquisitions from Tl-201 (dual-isotope procedure) and from Sestamibi (single-isotope procedure) and (2) in segments for which a diagnosis of ischemia, infarct, or normal perfusion was achieved. Mean effective dose was 8.3 mSv for dual-isotope but would decrease to 5.7 mSv for an expected rate of 37% of patients for whom rest-SPECT is not warranted. After a further background correction of Tl-201 images, the rest-stress difference in myocardial uptake was equivalent between dual- and single-procedures for identifying ischemic segments (respective areas-under-curves: 0.83 ± 0.03 and 0.81 ± 0.03).Conclusion: This original dual-isotope procedure provides acceptable radiation doses and consistent results, as compared with conventional single-isotope.

Details

ISSN :
15326551 and 10713581
Volume :
25
Database :
OpenAIRE
Journal :
Journal of Nuclear Cardiology
Accession number :
edsair.doi.dedup.....eecf5a7db679cb59eb70f08e9b2af210
Full Text :
https://doi.org/10.1007/s12350-017-0914-z