Back to Search
Start Over
Reduced esophageal heating in high‐power short‐duration atrial fibrillation ablation in the contact force catheter era
- Source :
- Pacing and Clinical Electrophysiology. 44:1185-1192
- Publication Year :
- 2021
- Publisher :
- Wiley, 2021.
-
Abstract
- BACKGROUND Atrial fibrillation (AF) ablation is alternative treatment to medical therapy. Most feared complication is atrioesophageal fistula METHODS: Observational, retrospective analysis of consecutive 355 patients undergoing first AF ablation. Low-power long-duration (LPLD) group contained 158 patients, with 121 (76.58%) having paroxysmal AF who underwent ablation with power 20/30W (anterior and posterior left atrial wall), 17 mL/min flow, and a contact force of 10-30 g for 30 s. High-power short-duration group (HPSD) contained 197 patients, with 113 (57.36%) having paroxysmal AF who underwent ablation at 45/50W of power with a contact force of 8-15 g/10-20 g and a 35 mL/min flow rate for 6-8 s on the anterior and the posterior left atrial wall, respectively. Both groups had pulmonary veins isolated and atrial flutter was ablated when needed. For patients not in sinus rhythm, cardioversion was performed before ablation RESULTS: There were no complications. LPLD group: Left atrial time 118.74 min, total 145.32 min, radiofrequency time 4317.99s, X-ray 13.42 min, and elevation of luminal esophageal temperature (LET) in 132 (84.53%) patients. HPSD group: Left atrial time 72.16 min, total 93.76 min, radiofrequency time 1511.29s, X-ray 7.6 min, and LET elevation in only 75 (38.07%) patients. A markedly higher rate of first-pass isolation was observed in HPSD compared to LPLD, 77.16% versus 13.29%, respectively. Recurrence occurred in 64 (40.50%) and 32 (16.24%) in 28.45 and 22.35 months in LPLD and HPSD patients, respectively. In LPLD, 10 patients were submitted to endoscopy, and one (10%) had mild erythema and in HPSD, 13 performed the endoscopy, with two (15.38%) patients showing mild erythema CONCLUSION: HPSD technique compared to the LPLD technique showed significant reduced radiofrequency and fluoroscopy times, higher rate of first-pass isolation, lower recurrence rate, and esophageal temperature elevation and may also have a protective effect avoiding incidental esophageal injury due to these findings.
- Subjects :
- Male
medicine.medical_specialty
Hot Temperature
Time Factors
medicine.medical_treatment
Catheter ablation
030204 cardiovascular system & hematology
Cardioversion
03 medical and health sciences
Esophagus
0302 clinical medicine
Internal medicine
Atrial Fibrillation
medicine
Humans
Sinus rhythm
030212 general & internal medicine
Retrospective Studies
Fibrillation
business.industry
Atrial fibrillation
General Medicine
Middle Aged
medicine.disease
Ablation
Catheter Ablation
Cardiology
Female
medicine.symptom
Cardiology and Cardiovascular Medicine
business
Complication
Atrial flutter
Subjects
Details
- ISSN :
- 15408159 and 01478389
- Volume :
- 44
- Database :
- OpenAIRE
- Journal :
- Pacing and Clinical Electrophysiology
- Accession number :