Back to Search Start Over

Comparison of delivery catheter-based and stylet-based right ventricular lead placement at the right ventricular septum under fluoroscopic guidance judged by cardiac CT (Mt. FUJI): a study protocol for the Mt. FUJI randomised controlled trial

Authors :
Satoru Suwa
Jun Tanabe
Ryo Sugiura
Manabu Ogita
Yoshihisa Naruse
Keisuke Miyajima
Masahiro Muto
Michio Ogano
Nobutake Kurebayashi
Tomoyuki Shiozawa
Yumi Kiyama
Eiko Nagata
Keiichi Odagiri
Yutaro Kaneko
Tomoaki Sakakibara
Taro Narumi
Satoshi Mogi
Kenichiro Suwa
Hayato Ohtani
Masao Saotome
Tuyoshi Urushida
Akira Mizukami
Hideyuki Hasebe
Keisuke Iguchi
Akiko Atsumi
Naoya Inoue
Tomoya Iwawaki
Tomotaka Suzuki
Takashi Ogane
Naoki Tsurumi
Yumiko Joko
Shuji Morikawa
Hideki Wada
Shintaro Takano
Jun Shitara
Shoichiro Yatsu
Taketo Sonoda
Kentaro Yasuda
Ryota Nishio
Daigo Takahashi
Go Ishikawa
Soushi Moriya
Kei Kimura
Kohei Sawasaki
Natsuko Hosoya
Yasushi Wakabayashi
Yoshitaka Kawaguchi
Tomoyuki Watanabe
Yasuyo Takashima
Ayako Okazaki
Kazuki Ito
Ryuta Henmi
Daichi Isomura
Hideki Saito
Yoshinobu Kato
Source :
BMJ Open, Vol 11, Iss 5 (2021), BMJ Open
Publication Year :
2021
Publisher :
BMJ Publishing Group, 2021.

Abstract

IntroductionPacing-induced cardiomyopathy occasionally occurs in patients undergoing pacemaker implantation. Although compared with right ventricular (RV) apical pacing, RV septal pacing can attenuate left ventricular dyssynchrony; the success rate of lead placement on the RV septum using the stylet system is low. Additionally, no randomised controlled trial has addressed the issue regarding the accuracy of RV lead placement on the RV septum using the stylet and delivery catheter systems. This study hypothesises that a newly available delivery catheter system can improve the accuracy of RV lead placement on the RV septum.Methods and analysisIn a multicentre, prospective, randomised, single-blind, controlled trial, 70 patients with pacemaker indication owing to atrioventricular block will be randomised to either the delivery catheter or stylet group before the pacemaker implantation procedure. The position of the RV lead tip will be assessed using ECG-gated cardiac CT in all patients within 4 weeks after pacemaker implantation. Lead tip positions are classified into three groups: (1) RV septum, (2) anterior/posterior edge of the RV septal wall and (3) RV free wall. The primary endpoint will be the success rate of RV lead tip placement on the RV septum, which will be evaluated using cardiac CT.Ethics and disseminationThis study will be conducted according to the stipulations of the Helsinki Declaration and the institutional review board of Hamamatsu University School of Medicine. The results of the study will be disseminated at several research conferences and will be published in peer-reviewed journals.Trial registration numberjRCTs042200014; Pre-results.

Details

Language :
English
ISSN :
20446055
Volume :
11
Issue :
5
Database :
OpenAIRE
Journal :
BMJ Open
Accession number :
edsair.doi.dedup.....ee028434b056c5bb3ace95528d4087b6