Back to Search Start Over

Comparative differences of mitral valve-in-valve implantation: A new mitral bioprosthesis versus current mosaic and epic valves

Authors :
William W. O'Neill
Thomas G. Caranasos
Richard S. Stack
Dee Dee Wang
Brian P. O'Neill
W. Randolph Chitwood
Source :
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac AngiographyInterventions. 99(3)
Publication Year :
2021

Abstract

OBJECTIVE Evaluate transcatheter mitral valve replacement (TMVR) valve-in-valve (VIV) outcomes in three different mitral bioprostheses (of comparable measured internal diameters) under stable hemodynamic and surgical conditions by bench, echocardiographic, computerized tomography (CT), and autopsy comparisons pre- and post-valve implantation in a porcine model under matched controlled conditions. BACKGROUND Impact of surgical bioprosthesis design on TMVR VIV procedures is unknown. METHODS Fifteen similar-sized Yorkshire pigs underwent pre-procedural CT screening. Twelve had consistent anatomic features and underwent implantation of mitral bioprostheses. Four valves from each of three manufacturers were implanted in randomized fashion: 27-mm Epic, 27-mm Mosaic, and 25-mm Mitris, followed by TMVR VIV with 26 Edwards Sapien3. Post-VIV, suprasternal TEE studies were performed to assess hemodynamic function, followed by a gated contrast CT. After euthanasia, animals underwent necropsy for anatomic evaluation. RESULTS All 12 animals had successful VIV implantation with no study deaths. The post vivMitris (3.77 ± 0.36)/(2.2 ± 0.25 mmHg) had the lowest peak/mean trans-mitral gradient and the vivEpic the highest (15.5 ± 2.55)/(7.09 ± 1.13 mmHg). All THVs (transcatheter heart valves) had greatest deformation within the center of the THV frame; with the smallest waist opening area in the vivEpic (329 ± 35.8 mm2 ) and greatest in the vivMitris (414 ± 33.12 mm2 ). Bioprosthetic frames without obvious radiopaque markers resulted in the most ventricular implantation of the THV's anteroseptal frame (Epic: -4.52 ± 0.76 mm), versus the most radiopaque bioprosthesis (Mitris: -1.18 ± 2.95 mm), and higher peak LVOT gradients (Epic: 4.82 ± 1.61 mmHg; Mitris: 2.91 ± 1.47 mmHg). CONCLUSIONS The current study demonstrates marked variations in hemodynamics, THV opening area, and anatomic dimensions among measured similarly sized mitral bioprostheses. These data suggest a critical need for understanding the potential impact of variations in bioprosthesis design on TMVR VIV clinical outcomes.

Details

ISSN :
1522726X
Volume :
99
Issue :
3
Database :
OpenAIRE
Journal :
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac AngiographyInterventions
Accession number :
edsair.doi.dedup.....edb467d4db19bfa0f5486f96847983ee