Back to Search
Start Over
Radiographic density changes may be associated with overloading and implant loss on short implants: A 5-year analysis of a randomized controlled clinical trial
- Source :
- Clinical implant dentistry and related researchREFERENCES. 24(6)
- Publication Year :
- 2022
-
Abstract
- To analyze changes in radiographic bone density around short implants with and without cantilevers at 5 years post-loading.Thirty-six patients with two adjacent posterior missing teeth participated in this randomized controlled clinical trial. All patients were randomly allocated to receive either two short implants (6 mm) with single-unit restorations (group TWO) or one single short implant (6 mm) with a cantilever restoration (group ONE-C). Patients were followed up at 6 months, 1, 3, and 5 years. Radiographic analysis was performed, through an arbitrary gray scale value (GSV) of the peri-implant bone, assessing the changes in radiographic density between groups and between time points. Differences in GSV between groups and over time were calculated using a generalized estimating equation to allow for adjustments for the correlation within individuals and between time points.At 5 years, 26 patients remained in the study (15 in group ONE-C; 11 in group TWO). Implant survival rates were 80.4% in group TWO and 84.2% in group ONE-C (p = 0.894). The radiographic analysis revealed that GSVs increased in both groups over time (p 0.001). The overall radiographic density was higher in group ONE-C than in group TWO in the maxilla (p = 0.030). Conversely, in the mandible, these significant differences between the groups were not found (p 0.05). Compared to the implants that survived, the implants that failed demonstrated a distinct radiographic density pattern (p 0.05).Within the limitations of the present study, the radiographic bone density in the maxilla appears to increase distinctly around short implants when cantilevers are used. In contrast, the radiographic density in the mandible appears to be unaffected by the use of a cantilever, suggesting a lower threshold of adaptation to occlusal forces and thus a higher susceptibility to overload and implant loss at earlier time points.
Details
- ISSN :
- 17088208
- Volume :
- 24
- Issue :
- 6
- Database :
- OpenAIRE
- Journal :
- Clinical implant dentistry and related researchREFERENCES
- Accession number :
- edsair.doi.dedup.....ed41a1876c930c0eb549a3b4b789069e