- Nuclear Science Symposium and Medical Imaging Conference, 21.-28.10.2017, Atlanta, GA, USA2017 IEEE NSS/MIC Conference Record: IEEE, 978-1-5386-2282-7, 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2017 Nuclear Science Symposium and Medical Imaging Conference, 21.-28.10.2017, Atlanta, GA, USA
- Publication Year :
- 2018
-
Abstract
- In-situ range verification of ion beams during dose delivery is a key for further improving the precision and reducing side effects of radiotherapy with particle beams. The detection and analysis of prompt gamma rays with respect to their emission points, emission time, and emission energy can provide corresponding means. Prompt gamma-ray imaging (PGI) has already been used for range verification in patient treatments with proton beams. The prompt gamma-ray timing (PGT) technique promises range verification at lower hardware expense with simpler detection systems superseding heavy collimators. After proving the principle, this technique is now being translated to the treatment room. The paper presents latest experimental results obtained with clinically applicable PGT hardware in irradiations of plexiglass targets in pencil beam scanning (PBS) mode with proton beams at clinical dose rates. The data were acquired with multiple PGT detection units while the distal layer of an artificial 1 Gy dose cube treatment plan was repeatedly delivered to a solid PMMA target that sometimes comprised a cylindrical air cavity of 5, 10, or 20 mm depth. The corresponding local range shifts were clearly detected and visualized by analyzing position or variance of the prompt gamma-ray timing peaks in PGT spectra assigned to the individual PBS spots. In this context, a major challenge concerning all prompt-gamma based techniques is examined and discussed: collecting the event statistics that is needed for range verification of single pencil beam spots at an accuracy level of a few millimeters.
- Subjects :
- Materials science
Proton
Particle therapy
Context (language use)
range verification
030218 nuclear medicine & medical imaging
treatment verification
03 medical and health sciences
0302 clinical medicine
Optics
proton therapy
Pencil-beam scanning
Proton therapy
throughput
Range (particle radiation)
business.industry
prompt gamma timing
Detector
prompt gamma imaging
Gamma ray
3. Good health
030220 oncology & carcinogenesis
gamma spectroscopy
prompt gamma rays
business
Energy (signal processing)
Subjects
Details
- Language :
- English
- ISBN :
- 978-1-5386-2282-7
- ISBNs :
- 9781538622827
- Database :
- OpenAIRE
- Journal :
- Nuclear Science Symposium and Medical Imaging Conference, 21.-28.10.2017, Atlanta, GA, USA2017 IEEE NSS/MIC Conference Record: IEEE, 978-1-5386-2282-7, 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2017 Nuclear Science Symposium and Medical Imaging Conference, 21.-28.10.2017, Atlanta, GA, USA
- Accession number :
- edsair.doi.dedup.....ed29f0eeb396a003ab3c403a36d38d50