- Arterial compliance (C) is related to the elasticity, size, and geometrical distribution of arteries. Compliance is a determinant of the load that impedes ventricular ejection. Measuring compliance is difficult, particularly in the pulmonary circulation in which resistive and compliant vessels overlap. Comparing different methods for quantification of compliance to a method that involves a continuous flow might help to identify the optimal method. Pulmonary arterial compliance was computed in six pigs based on the stroke volume to pulse pressure ratio, diastolic decay exponential fitting, area method, and the pulse pressure method (PPM). Compliance measurements were compared to those obtained under continuous flow conditions through a right ventricular bypass (Heartware Inc. Miami Lakes, FL, USA). Compliance was computed for various flows using diastolic decay exponential fitting after an abrupt interruption of the pump. Under the continuous flow conditions, resistance (R) was a decreasing function of the flow, and the fitting to P = e-t/RC yielded a pulmonary time constant (RC) of 2.06 s (± 0.48). Compliance was an increasing function of flow. Steady flow inter-method comparisons of compliance under pulsatile flow conditions showed large discrepancies and values (7.23 ± 4.47 mL/mmHg) which were lower than those obtained under continuous flow conditions (10.19 ± 1 0.31 mL/mmHg). Best agreement with steady flow measurements is obtained with the diastolic decay method. Resistance and compliance are both flow-dependent and are inversely related in the pulmonary circulation. The dynamic nature of the pulsatile flow may induce a non-uniformly distributed compliance, with an influence on the methods of measurement.<br />SCOPUS: ar.j<br />info:eu-repo/semantics/published
- Subjects :
- Pulmonary and Respiratory Medicine
medicine.medical_specialty
lcsh:Diseases of the circulatory (Cardiovascular) system
Technology and Engineering
OCCLUSION
Diastole
Pulsatile flow
EXERCISE
030204 cardiovascular system & hematology
03 medical and health sciences
0302 clinical medicine
Internal medicine
medicine
Medicine and Health Sciences
heart-assist device
lcsh:RC705-779
VASCULAR-RESISTANCE
HYPERTENSION
business.industry
CAPILLARY-PRESSURE
Time constant
Généralités
Stroke volume
lcsh:Diseases of the respiratory system
medicine.disease
Pulse pressure
Exponential function
medicine.anatomical_structure
CAPACITANCE
DOGS
030228 respiratory system
lcsh:RC666-701
pulmonary circulation
Heart failure
Vascular resistance
Cardiology
HEART-FAILURE
elasticity
HEALTH
business
Research Article
Subjects
Details
- Language :
- English
- ISSN :
- 20458932 and 20458940
- Database :
- OpenAIRE
- Journal :
- PULMONARY CIRCULATION, Pulmonary Circulation, Vol 8 (2018), Pulmonary circulation, 8 (2, Pulmonary Circulation
- Accession number :
- edsair.doi.dedup.....ecf3ee8c130b743d497c4462e1f3b16e