Back to Search
Start Over
Evaluation of fully automated a priori MCO treatment planning in VMAT for head-and-neck cancer
- Source :
- Physica Medica. 87:31-38
- Publication Year :
- 2021
- Publisher :
- Elsevier BV, 2021.
-
Abstract
- Purpose Automated planning techniques aim to reduce manual planning time and inter-operator variability without compromising the plan quality which is particularly challenging for head-and-neck (HN) cancer radiotherapy. The objective of this study was to evaluate the performance of an a priori-multicriteria plan optimization algorithm on a cohort of HN patients. Methods A total of 14 nasopharyngeal carcinoma (upper-HN) and 14 “middle-lower indications” (lower-HN) previously treated in our institution were enrolled in this study. Automatically generated plans (autoVMAT) were compared to manual VMAT or Helical Tomotherapy planning (manVMAT-HT) by assessing differences in dose delivered to targets and organs at risk (OARs), calculating plan quality indexes (PQIs) and performing blinded comparisons by clinicians. Quality control of the plans and measurements of the delivery times were also performed. Results For the 14 lower-HN patients, with equivalent planning target volume (PTV) dosimetric criteria and dose homogeneity, significant decrease in the mean doses to the oral cavity, esophagus, trachea and larynx were observed for autoVMAT compared to manVMAT-HT. Regarding the 14 upper-HN cases, the PTV coverage was generally significantly superior for autoVMAT which was also confirmed with higher calculated PQIs on PTVs for 13 out of 14 patients, whereas PQIs calculated on OARs were generally equivalent. Number of MUs and total delivery time were significantly higher for autoVMAT compared to manVMAT. All plans were considered clinically acceptable by clinicians. Conclusions Overall superiority of autoVMAT compared to manVMAT-HT plans was demonstrated for HN cancer. The obtained plans were operator-independent and required no post-optimization or manual intervention.
- Subjects :
- Organs at Risk
Larynx
medicine.medical_specialty
medicine.medical_treatment
Biophysics
Planning target volume
General Physics and Astronomy
Tomotherapy
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
medicine
Humans
Radiology, Nuclear Medicine and imaging
Radiation treatment planning
business.industry
Radiotherapy Planning, Computer-Assisted
Head and neck cancer
Radiotherapy Dosage
General Medicine
medicine.disease
Cephalosporins
medicine.anatomical_structure
Fully automated
Head and Neck Neoplasms
030220 oncology & carcinogenesis
Cancer Radiotherapy
Radiotherapy, Intensity-Modulated
Radiology
business
Previously treated
Subjects
Details
- ISSN :
- 11201797
- Volume :
- 87
- Database :
- OpenAIRE
- Journal :
- Physica Medica
- Accession number :
- edsair.doi.dedup.....ec51cb00c9bbabd6d0cc15e2d58f644e
- Full Text :
- https://doi.org/10.1016/j.ejmp.2021.05.037