Back to Search
Start Over
High polarity analytes in food - enrofloxacin and sulfadiazine in bovine tissue (CCQM-K141)
- Source :
- Metrologia. 56:08005
- Publication Year :
- 2019
- Publisher :
- IOP Publishing, 2019.
-
Abstract
- Within the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantitè de Matiére (CCQM), key comparison CCQM-K141 and associated pilot study CCQM-P178 were coordinated by the National Research Council Canada (NRC). This comparison was a Track A key comparison that formed part of the OAWG 10-year strategic plan. The comparison demonstrated capabilities for measuring high-polarity analytes in a high-fat and high-protein matrix. The measurand chosen as the model system was enrofloxacin and sulfadiazine in bovine tissue. Thirteen National Metrology Institutes or Designated Institutes participated in the CCQM-K141, while two National Metrology Institutes participated in CCQM-P178. The bovine muscle tissue study material was derived from a single live animal that was administered with chemical based pharmaceutical agents prior to processing. Therefore, the study material was naturally incurred, providing a true test of extraction procedures relative to more commonly encountered spiked materials. NRC confirmed excellent homogeneity and stability of the material prior to shipping. Three 10 g bottles of freeze dried powdered muscle tissue were supplied. NRC also provided isotopically labelled solutions of the two measurands, 13C6-sulfadiazine and enrofloxacin-d5 (HI Salt), to those interested in using isotope dilution mass spectrometry (IDMS) methodologies. Procurement and purity assignment with appropriate metrological traceability of native calibrants were the responsibility of individual participants. The study required extraction, clean-up, analytical separation, and selective detection of the analytes. The level of agreement was reasonable given the measurands and matrix were new for most laboratories. The KCRV values and their uncertainties at the 95% confidence level of 57.81 ± 2.57 μg/kg for enrofloxacin and 2285 ± 68 μg/kg for sulfadiazine were calculated using the DSL means. While one participant's value was voluntarily excluded from the KCRV calculations for enrofloxacin, all other participants demonstrated equivalence for both measurands. Significant effort was undertaken post-study to identify the major sources of variability between results. In particular, the various extraction conditions used by participants were investigated thoroughly. While there appeared to be a correlation between highly acidic conditions and higher recovery, this was not definitive and could not be confirmed. The form of standards employed (i.e. free base vs salts) and potential differential solubility between forms was also a suspected source of variability. Biases could also have been introduced with the choice of solvents used for standard preparation, with some solvents better able to minimize adsorption of the analytes to glass surfaces. KEY WORDS FOR SEARCH enrofloxacin, sulfadiazine, bovine tissue, incurred, key comparison Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- Subjects :
- Analyte
Chromatography
Chemistry
Polarity (physics)
sulfadiazine
General Engineering
bovine tissue
incurred
Gören A. C. , -High polarity analytes in food - enrofloxacin and sulfadiazine in bovine tissue (CCQM-K141)-, Metrologia, cilt.56, no.805, ss.805, 2019
Sulfadiazine
medicine
Enrofloxacin
enrofloxacin
key comparison
Bovine tissue
medicine.drug
Subjects
Details
- ISSN :
- 16817575 and 00261394
- Volume :
- 56
- Database :
- OpenAIRE
- Journal :
- Metrologia
- Accession number :
- edsair.doi.dedup.....ebee0d2bde15501560543bbc378bc3a8
- Full Text :
- https://doi.org/10.1088/0026-1394/56/1a/08005