Back to Search
Start Over
3gamma medical imaging with a liquid xenon Compton Camera and 44Sc radionuclide
- Source :
- Acta Physica Polonica B, Acta Physica Polonica B, Jagellonian University, Cracow, 2017, 48 (10), ⟨10.5506/APhysPolB.48.1661⟩, Acta Physica Polonica B, 2017, 48 (10), ⟨10.5506/APhysPolB.48.1661⟩
- Publication Year :
- 2017
- Publisher :
- HAL CCSD, 2017.
-
Abstract
- International audience; The development of a liquid xenon Compton camera called XEMIS2 (XEnon Medical Imaging System) is a step forward to a new type of medical imaging based on the use of 44Sc radionuclide emitting two annihilation rays and a third high energy ray simultaneously. The single phase TPC (Time Projection Chamber) under construction, containing nearly 200 kg of xenon, is designed to measure most of the Compton interactions in the active area with a sub-millimetre position resolution and a good energy resolution of 4% on 511 keV photopeak. The intersection of the Compton cone surface from the third ray with the line of response from the two annihilation rays allows to localize the radionuclide with a precision (FWHM) of about 1 cm along this line. The large field of view of such a liquid xenon camera combined with the 3 imaging technique will provide a good quality image while keeping the injected activity at a very low level. XEMIS2 will be installed in the Nantes University Hospital in order to demonstrate its capability to image small animals injected with a low activity of only 20 kBq in 20 mn acquisition time. To achieve this goal, a precise measurement of the ionization signal is provided by a pixelized anode, shielded by a Frisch Grid and read out by a low noise front-end electronics. In addition, new cryogenic and purification subsystems have been tested, allowing safe recovery of xenon in liquid phase at flow rates of about 1 ton per hour.
- Subjects :
- medicine.medical_specialty
General Physics and Astronomy
chemistry.chemical_element
[SDV.CAN]Life Sciences [q-bio]/Cancer
01 natural sciences
Signal
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Quality (physics)
Xenon
Optics
[SDV.CAN] Life Sciences [q-bio]/Cancer
Ionization
0103 physical sciences
medicine
Medical imaging
Medical physics
Physics
Annihilation
Time projection chamber
010308 nuclear & particles physics
business.industry
Full width at half maximum
chemistry
business
Subjects
Details
- Language :
- English
- ISSN :
- 05874254 and 15095770
- Database :
- OpenAIRE
- Journal :
- Acta Physica Polonica B, Acta Physica Polonica B, Jagellonian University, Cracow, 2017, 48 (10), ⟨10.5506/APhysPolB.48.1661⟩, Acta Physica Polonica B, 2017, 48 (10), ⟨10.5506/APhysPolB.48.1661⟩
- Accession number :
- edsair.doi.dedup.....ebdb3fbc5a2efddb73204325203d1339