Back to Search Start Over

High-power tests of a remote steering launcher mock-up at 140 GHz

Authors :
B Plaum
G Gantenbein
W Kasparek
K Schwörer
M Grünert
H Braune
V Erckmann
F Hollmann
L Jonitz
H Laqua
G Michel
F Noke
F Purps
A Bruschi
S Cirant
F Gandini
A G A Verhoeven
ECRH group at IPP Greifswald
ECRH group at FZK Karlsruhe
ECRH group at IPF Stuttgart
Source :
Third IAEA Technical Meeting on ECRH Physics and Technology in ITER, pp. 120–129, Como, 2005, info:cnr-pdr/source/autori:Plaum B.; Gantenbein G.; Kasparek W.; Schwörer K.; Grünert M.; Braune H.; Erckmann V.; Hollmann F.; Jonitz L.; Laqua H.; Michel G.; Noke F.; Purps F.; Bruschi A.; Cirant S.; Gandini F.; Verhoeven A.G.A.; ECRH groups at IPP Greifswald; FZK Karlsruhe and IP/congresso_nome:Third IAEA Technical Meeting on ECRH Physics and Technology in ITER/congresso_luogo:Como/congresso_data:2005/anno:2005/pagina_da:120/pagina_a:129/intervallo_pagine:120–129
Publication Year :
2005
Publisher :
IOP Publishing, 2005.

Abstract

This paper reports the results of the high-power test of a remote steering launcher mock-up at 140 GHz, which were performed at the ECRH installation for the future stellarator W7-X at IPP Greifswald. The mock-up test system consists of a 6.62 m long corrugated square waveguide with a steerable optic at the entrance and various diagnostics at the exit of the waveguide. A straight and a dog-leg version of the launcher were investigated. The high-power tests of the straight setup have been performed with powers up to P0 = 700 kW (typically 500 kW) and pulse lengths of up to 10 seconds. For both polarizations (parallel and perpendicular to the steering plane), no arcing was observed in spite of the fact, that the experiments were performed under ambient atmospheric conditions. After the integration of 2 mitre bends in the setup, arcing limited the usable parameter range. The ohmic loss PΩ of the waveguide was measured via the temperature increase of the waveguide wall, and was used to calibrate the calculated angular dependence of the total ohmic losses of the waveguide. Short-pulse radiation pattern measurements with thermographic recording show high beam quality and confirm the steering range of −12° < < 12°.

Details

ISSN :
17426596 and 17426588
Volume :
25
Database :
OpenAIRE
Journal :
Journal of Physics: Conference Series
Accession number :
edsair.doi.dedup.....eaf7a53f50ae450d39cfc67701996e63
Full Text :
https://doi.org/10.1088/1742-6596/25/1/016